Functions
SiBE041134EB
2
List of Functions
1. Functions
Category
Functions
F
T
XS2
0
/2
5
K2
V1
B
R
X
S2
0
/2
5
K2
V1
B, R
X
S2
0
/2
5
K3
V1
B
R
X
S
2
0/
25
L2
V
1
B
Category
Functions
F
T
XS2
0
/2
5
K2
V1
B
R
X
S2
0
/2
5
K2
V1
B, R
X
S2
0
/2
5
K3
V1
B
R
X
S
2
0/
25
L2
V
1
B
Basic
Functions
Inverter (with inverter power control)
z
Health &
Cleanliness
Air-purifying filter
—
Operation limit for cooling (°CDB)
–10
~ 46
Photocatalytic deodorizing filter
—
Operation limit for heating (°CWB)
–
15
~ 18
Air-purifying filter with photocatalytic
deodorizing function
—
PAM control
z
Titanium apatite photocatalytic
air-purifying filter
z
Standby electricity saving
z
Compressor
Oval scroll compressor
—
Air filter (prefilter)
z
Swing compressor
z
Wipe-clean flat panel
z
Rotary compressor
—
Washable grille
—
Reluctance DC motor
z
MOLD PROOF operation
—
Comfortable
Airflow
Power-airflow flap
z
Good-sleep cooling operation
—
Power-airflow dual flaps
—
Timer
WEEKLY TIMER operation
z
Power-airflow diffuser
—
24-hour ON/OFF TIMER
z
Wide-angle louvers
z
NIGHT SET mode
z
Auto-swing (up and down)
z
Worry Free
(Reliability &
Durability)
Auto-restart (after power failure)
z
Auto-swing (right and left)
—
Self-diagnosis (R/C, LED)
z
3-D airflow
—
Wiring error check function
—
COMFORT AIRFLOW operation
z
Anti-corrosion treatment of outdoor heat
exchanger
z
Comfort
Control
Auto fan speed
z
Flexibility
Multi-split / split type compatible indoor unit
z
Indoor unit quiet operation
z
H/P, C/O compatible indoor unit
—
NIGHT QUIET mode (automatic)
—
Flexible power supply correspondence
—
OUTDOOR UNIT QUIET operation (manual)
z
Chargeless
10 m
2-area INTELLIGENT EYE operation
—
Either side drain (right or left)
z
INTELLIGENT EYE operation
z
Power selection
—
Quick warming function (preheating control)
z
Remote
Control
5-room centralized controller (option)
z
Remote control adaptor
(normal open pulse contact) (option)
z
Hot-start function
z
Automatic defrosting
z
Remote control adaptor
(normal open contact) (option)
z
Operation
Automatic operation
z
Program dry operation
z
DIII-NET compatible (adaptor) (option)
z
Fan only
z
Remote
Controller
Wireless
z
Lifestyle
Convenience
New POWERFUL operation
(non-inverter)
—
Wired (option)
z
Inverter POWERFUL operation
z
Priority-room setting
—
COOL/HEAT mode lock
—
HOME LEAVE operation
—
ECONO operation
z
Indoor unit
ON/OFF
button
z
Signal receiving sign
z
R/C with back light
z
Temperature display
—
Note:
z
: Available
— : Not available
: Lower limit can be extended by cutting jumper.
(Facility use only)
Refer to page 110 for details.