SiBE04-809
Indoor Unit
Removal Procedure
141
1.7
Removal of Outlet Grille
Procedure
Warning
Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Step
Procedure
Points
Remove the front grille.
Remove the assembly of
the reduction motor.
1. Remove the outlet grille.
1
Insert your finger into
the hole and push up
the hook to release it.
The outlet grille has 4
holes.
2
Lift up the lower part of
the grille to release the
hook on the upper
backside.
3
Rotate the upper part of
the grille to release the
hook on the lower back-
side.
Pull out the grille.