Indoor Unit
SiBE04-809
126
Removal Procedure
1.2
Removal of
Front Grille
Procedure
Warning
Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Step
Procedure
Points
1. Remove the front panel.
Start the removal procedure
of front grille when the
panels are closed.
Slide the front panel side to
side to release each axis.
When assembling, align the
right and left axes with
grooves in turn and insert
them to the end.
1
Open the front panel to
the horizontal position.
Release the both sides
pivots and remove the
front panel.
2. Remove the slot-in panel.
1
Pull the lower side of
the panel.
2
Lift the panel and
remove from the slots.
Slot-in panel
(R5009)