3
|
Components
Service manual
112
EBLA09~16DA + EDLA09~16DA
Daikin Altherma 3 M
ESIE20-06A – 2021.03
Is the problem solved?
Action
Yes
No further actions required.
No
heater and continue with the next
procedure.
To remove the backup heater contactor(s)
Prerequisite:
Stop the unit operation via the user interface.
Prerequisite:
Turn off the respective circuit breaker of the unit and the backup
heater.
Prerequisite:
Remove the required plate work, see
230].
1
Disconnect the wiring from the backup heater contactor terminals.
2
Remove the screws and remove the backup heater contactor(s) from the
switch box.
3
To install the backup heater contactor(s), see
To install the backup heater contactor(s)
1
Install the backup heater contactor(s) in the switch box and fix them using the
screws.
2
Connect the wiring to the correct backup heater contactor terminals.
Is the problem solved?
Action
Yes
No further actions required.
No
heater and continue with the next
procedure.
3.3.2 Backup heater kit
Checking procedures
INFORMATION
It is recommended to perform the checks in the listed order.
To perform a resistance check of the backup heater
Prerequisite:
Stop the unit operation via the user interface.
Prerequisite:
Turn OFF the respective circuit breaker.
1
Remove the required plate work, see