4 Operation

Operation manual

12

ETVH/9W(G) + ETBH/9W

Daikin Altherma 3 H HT F+W

4P586455-1 – 2019.07

In menu…

You can read out…

[8.3] 

Dealer information

Contact/helpdesk number

[8.4] 

Sensors

Room, tank or domestic hot
water, outside, and leaving water
temperature (if applicable)

[8.5] 

Actuators

Status/mode of each actuator

Example: 

Domestic hot water

pump ON/OFF

[8.6] 

Operation modes

Current operation mode

Example: 

Defrost/oil return

mode

[8.7] 

About

Version information about the
system

[8.8] 

Connection status

Information about the connection
status of the unit, the room
thermostat and the LAN adapter.

[8.9] 

Running hours

Running hours of specific system
components

4.6

Space heating/cooling control

4.6.1

Setting the space operation mode

About space operation modes

Depending  on  your  heat  pump  model,  you  have  to  tell  the  system
which space operation mode to use: heating or cooling.

If a … heat pump

model is installed

Then…

Heating/cooling

The system can heat up and cool down a
space. You have to tell the system which
space operation mode to use.

Heating only

The system can heat up a space, but
NOT cool down a space. You do NOT
have to tell the system which space
operation mode to use.

To tell the system which space operation to use, you can:

You can…

Location

Check

 which space operation mode is

currently used

.

Home screen

Set

 the space operation 

mode 

permanently. Main menu

Restrict

 

automatic changeover

 according

to a monthly schedule.

To set the space operation mode

1

Go to [4.1]: 

Space heating/cooling

 > 

Operation

mode

2

Select one of the following options:

Heating

: Only heating mode

Cooling

: Only cooling mode

Automatic

The 

operation 

mode 

changes

automatically  based  on  the  outdoor  temperature.
Restricted  according  to  the  operation  mode
schedule.

To restrict automatic changeover according to a schedule

Conditions: 

You set the space operation mode to 

Automatic

.

1

Go to [4.2]: 

Space heating/cooling

 > 

Operation

mode schedule

.

2

Select a month.

3

For each month, select an option:

Reversible

: Not restricted

Heating only

: Restricted

Cooling only

: Restricted

4

Confirm the changes.

4.6.2

To change the desired room temperature

During room temperature control, you can use the room temperature
setpoint screen to read out and adjust the desired room temperature.

1

Go to [1]: 

Room

.

Room

1

2

Adjust the desired room temperature.

+

21

°C

1

a

b

Room

a

 Actual room temperature

b

 Desired room temperature

If scheduling is on after changing the desired room temperature

▪ The  temperature  will  stay  the  same  as  long  as  there  is  no

scheduled action.

▪ The  desired  room  temperature  will  return  to  its  scheduled  value

whenever a scheduled action occurs.

You  can  avoid  scheduled  behaviour  by  (temporarily)  turning  off
scheduling.

To turn off room temperature scheduling

1

Go to [1.1]: 

Room

 > 

Schedule

.

2

Select 

No

.

4.6.3

To change the desired leaving water
temperature

INFORMATION

The  leaving  water  is  the  water  that  is  sent  to  the  heat
emitters.  The  desired  leaving  water  temperature  is  set  by
your  installer  in  accordance  with  the  heat  emitter  type.
Only adjust the leaving water temperature settings in case
of problems.

You  can  use  the  leaving  water  temperature  setpoint  screen  to  read
out and adjust the desired leaving water temperature.

Содержание Altherma ETBH16DA6V

Страница 1: ...H HT F W English Operation manual Daikin Altherma 3 H HT F W ETVH16S18DA6V G ETVH16S23DA6V G ETVH16S18DA9W G ETVH16S23DA9W G ETVX16S18DA6V G ETVX16S23DA6V G ETVX16S18DA9W G ETVX16S23DA9W G ETBH16DA6V...

Страница 2: ...ve 15 4 9 2 2 points curve 16 4 9 3 Slope offset curve 16 4 9 4 Using weather dependent curves 17 5 Energy saving tips 17 6 Maintenance and service 18 6 1 Overview Maintenance and service 18 7 Trouble...

Страница 3: ...items for the user are now visible 1234 Advanced user 2 2 Space heating cooling To turn room temperature control ON or OFF 1 Go to C 1 Operation Room Operation Room Space heating cooling On On C 1 2 S...

Страница 4: ...lope is changed the new preferred temperature at X1 is unequally higher than the preferred temperature at X2 X1 X2 c d Y1 Y2 Y3 Y4 a b Offset When offset is changed the new preferred temperature at X1...

Страница 5: ...ndent curve There are 2 types of WD curves slope offset curve default and 2 points curve If needed you can change the type in 2 E Main zone WD curve type The way to adjust the curve depends on the typ...

Страница 6: ...ope com support and manuals product information Addendum book for optional equipment Additional info about how to install optional equipment Format Paper in the box of the unit Digital files on http w...

Страница 7: ...y the help text in case of a malfunction 418 for more information LCD screen The LCD screen has a sleeping function After a certain time of non interaction with the user interface the screen darkens P...

Страница 8: ...e Gas price 8 Information Energy data Malfunction history Dealer information Sensors Actuators Operation modes About Connection status Running hours B User profile C Operation Room Space heating cooli...

Страница 9: ...y Heat pump failure and system operates in Emergency mode or heat pump is forced off d Current date and time e Smart energy e1 Smart energy is available via solar panels or smart grid e2 Smart energy...

Страница 10: ...e applicable symbol for your main zone emitter type Set the leaving water temperature for the main zone 3 Additional zone Restriction Only displayed if there are two leaving water temperature zones Sh...

Страница 11: ...6 bar 55 19 42 18 c 1 6 bar 55 19 42 18 d c Space heating cooling operation ON d Space heating cooling operation OFF Tank heating operation 1 6 bar 55 19 42 18 e 1 6 bar 55 19 42 18 f e Tank heating...

Страница 12: ...cooling Operation mode 2 Select one of the following options Heating Only heating mode Cooling Only cooling mode Automatic The operation mode changes automatically based on the outdoor temperature Re...

Страница 13: ...e tank to produce hot water is at night because the space heating demand is lower Example t 60 C 00 00 07 00 50 C 15 C 40 C 14 00 21 00 1 2 3 4 5 Tt Tt DHW tank temperature t Time Initially the DHW ta...

Страница 14: ...temperature control is active you can program the main zone schedule instead 1 Go to the schedule 2 optional Clear the content of the whole week schedule or the content of a selected day schedule 3 Pr...

Страница 15: ...each character of the schedule name 4 To name the current schedule browse through the character list and confirm the selected character The schedule name can contain up to 15 characters 5 Confirm the...

Страница 16: ...the next temperature Confirm changes and proceed 4 9 3 Slope offset curve Slope and offset Define the weather dependent curve by its slope and offset Change the slope to differently increase or decrea...

Страница 17: ...curve INFORMATION Maximum and minimum setpoints You cannot configure the curve with temperatures that are higher or lower than the set maximum and minimum setpoints for that zone or for the tank When...

Страница 18: ...contact your installer for more information WARNING FLAMMABLE MATERIAL The refrigerant inside this unit is mildly flammable WARNING The appliance shall be stored in a room without continuously operati...

Страница 19: ...er automatically takes over the heat load and the booster heater in the optional tank takes over the domestic hot water production When Emergency is set to Manual and a heat pump failure occurs the do...

Страница 20: ...mantling of the system treatment of the refrigerant oil and other parts MUST comply with applicable legislation Units MUST be treated at a specialised treatment facility for reuse recycling and recove...

Страница 21: ......

Страница 22: ......

Страница 23: ......

Страница 24: ...4P586455 1 2019 07 Copyright 2019 Daikin 4P586455 1 0000000V...

Отзывы: