7
|
Unit installation
Installer reference guide
70
08CA + EHY EHYHBH/X08A + EHYKOMB33AA
Daikin Altherma hybrid heat pump
4P355634-1G – 2022.09
R
R
D
D
R/D=1
R/D=0.5
For a dual pipe connection, all defined lengths assume a diameter of 80 mm.
Sample calculation for dual pipe application
L6
L4
L3
L1
L2
L5
Pipe
Pipe length
Total pipe length
Flue pipe
L1+L2+L3+(2×2) m
13 m
Air supply
L4+L5+L6+(2×2) m
12 m
Total piping length = sum of the straight pipe l sum of the equivalent pipe
length of bends/elbows.
7.6.4 Appliance categories and pipe lengths
Following installation methods are supported by the manufacturer.