![Daikin Altherma EHYHBH05A Series Скачать руководство пользователя страница 60](http://html1.mh-extra.com/html/daikin/altherma-ehyhbh05a-series/altherma-ehyhbh05a-series_installers-reference-manual_4142548060.webp)
7
|
Unit installation
Installer reference guide
60
08CA + EHY EHYHBH/X08A + EHYKOMB33AA
Daikin Altherma hybrid heat pump
4P355634-1G – 2022.09
b
a
a
Protective cardboard
b
Instruction sheet
7.3.5 To provide drainage
▪
Avoid installation places where water leaking from the unit due to a blocked
drain pan can cause damage to the location.
▪
Make sure that condensation water can be evacuated properly.
▪
Install the unit on a base to make sure that there is proper drainage in order to
avoid ice accumulation.
▪
Prepare a water drainage channel around the foundation to drain waste water
away from the unit.
▪
Avoid drain water flowing over the footpath, so that it does NOT become slippery
in case of ambient freezing temperatures.
▪
If you install the unit on a frame, install a waterproof plate within 150 mm of the
bottom side of the unit in order to prevent water from getting into the unit and
to avoid drain water dripping (see the following figure).
NOTICE
If the drain holes of the outdoor unit are blocked up, provide space of at least
300 mm below the outdoor unit.
An additional drain pan kit (EKDP008CA) can be used to gather the drain water. The
drain pan kit consists of:
b
a
a
Drain pan
b
U-beams