Daikin Altherma EBLQ016CAV3 Скачать руководство пользователя страница 23

8 Troubleshooting

User reference guide

23

EBLQ+EDLQ011~W1 + EK(2)CB
EKMB9W1
Daikin Altherma low temperature monobloc
4P522035-1 – 2018.01

▪ Keep the area around the unit clean.

▪ Keep the user interface clean with a soft damp cloth. Do NOT use

any detergents.

▪ Regularly check if the water pressure is above 1 bar.

Refrigerant

This  product  contains  fluorinated  greenhouse  gases.  Do  NOT  vent
gases into the atmosphere.

Refrigerant type: R410A

Global warming potential (GWP) value: 2087.5

NOTICE

In  Europe,  the 

greenhouse  gas  emissions

  of  the  total

refrigerant charge in the system (expressed as tonnes CO

2

equivalent) is used to determine the maintenance intervals.
Follow the applicable legislation.

Formula  to  calculate  the  greenhouse  gas  emissions:

GWP value of the refrigerant × Total refrigerant charge [in
kg] / 1000

Please contact your installer for more information.

WARNING

The refrigerant in the system is safe and normally does not
leak. If the refrigerant leaks in the room, contact with a fire
of  a  burner,  a  heater  or  a  cooker  may  result  in  a  harmful
gas.

Turn  off  any  combustible  heating  devices,  ventilate  the
room and contact the dealer where you purchased the unit.

Do not use the system until a service person confirms that
the portion where the refrigerant leaks is repaired.

7.2

To find the contact/helpdesk
number

Prerequisite: 

You  switched  the  permission  level  to  Advanced  end

user.

1

Go  to  [6.3.2]: 

  >  Information  >  Error  handling  >  Contact/

helpdesk number.

8

Troubleshooting

8.1

Overview: Troubleshooting

If a malfunction occurs,   is displayed on the home pages. You can
press 

 to display more information about the malfunction.

For  the  symptoms  listed  below,  you  can  try  to  solve  the  problem
yourself. For any other problem, contact your installer. You can find
the contact/helpdesk number via the user interface.

8.2

To check the error history

Prerequisite: 

Only available if   is displayed on the home pages.

1

Go to [6.3.1]: 

 > Information > Error handling > Error history.

8.3

To check the warning history

Prerequisite: 

Only available if   is displayed on the home pages.

1

Go  to  [6.3.1]: 

  >  Information  >  Error  handling  >  Warning

history.

8.4

Symptom: You are feeling too cold
(hot) in your living room

Possible cause

Corrective action

The desired room temperature is
too low (high).

Increase (decrease) the desired
room temperature.

If the problem recurs daily, do
one of the following:

▪ Increase  (decrease)  the  room

temperature preset value.

▪ Adjust  the  room  temperature

schedule.

The desired room temperature
cannot be reached.

Increase the desired leaving
water temperature in accordance
with the heat emitter type.

8.5

Symptom: The water at the tap is
too cold

Possible cause

Corrective action

You ran out of domestic hot
water because of unusual high
consumption.

If you immediately need domestic
hot water, activate the DHW tank
booster mode. However, this
consumes extra energy.

If you can wait, overrule
(increase) the active or next
scheduled desired temperature
so that more hot water will be
produced exceptionally.

If the problems recurs daily, do
one of the following:

▪ Increase 

the 

DHW 

tank

temperature preset value.

▪ Adjust 

the 

DHW 

tank

temperature 

schedule.

Example: 

Program 

to

additionally 

heat 

up 

the

DHW  tank  to  a  preset  value
(Storage  eco  =  lower  tank
temperature) during the day.

The desired DHW tank
temperature is too low.

8.6

Symptom: Heat pump failure

When the heat pump fails to operate, the backup heater and booster
heater  can  serve  as  an  emergency  heater  and  either  automatically
or non-automatically take over the heat load.

▪ When  auto  emergency  is 

activated

  and  a  heat  pump  failure

occurs:

▪ The backup heater will automatically take over the heat load.

▪ The booster heater will automatically take over the domestic hot

water production.

▪ When  auto  emergency  is 

not  activated

  and  a  heat  pump  failure

occurs, the domestic hot water and space heating operations will
stop  and  need  to  be  recovered  manually.  The  user  interface  will
then  ask  you  to  confirm  whether  the  backup  heater  or  booster
heater can take over the heat load or not.

When the heat pump fails,   will appear on the user interface.

Содержание Altherma EBLQ016CAV3

Страница 1: ...English User reference guide Daikin Altherma low temperature monobloc EBLQ011CAV3 EBLQ014CAV3 EBLQ016CAV3 EBLQ011CAW1 EBLQ014CAW1 EBLQ016CAW1 EDLQ011CAV3 EDLQ014CAV3 EDLQ016CAV3 EDLQ011CAW1 EDLQ014CA...

Страница 2: ...g and programming schedules 16 4 7 3 Schedules Example 17 4 7 4 Predefined schedules Room temperature leaving water temperature main 18 4 7 5 Predefined schedules Leaving water temperature additional...

Страница 3: ...ive consequences for the environment and human health For more information contact your installer or local authority Batteries are marked with the following symbol This means that the batteries may NO...

Страница 4: ...Space heating cooling control How to control space heating cooling Setting the space operation mode Controlling the temperature Domestic hot water control How to control domestic hot water Reheat mode...

Страница 5: ...e User permission level Installer Defrost oil return mode is active Hot start mode is active Emergency operation is active 4 3 Basic usage 4 3 1 Using home pages About home pages You can use the home...

Страница 6: ...down a space You have to tell the system which space operation mode to use Heating only The system can heat up a space but NOT cool down a space You do NOT have to tell the system which space operatio...

Страница 7: ...water temperature control 3 Only for room thermostat control Go to the main leaving water temperature home page LWT main and check the following Is displayed next to the set point Then leaving water s...

Страница 8: ...The mode will return to Scheduled according to the overrule period Example Temporarily overruling the schedule AND changing the mode to preset value You have configured the following settings Setting...

Страница 9: ...3 hours Then you can do the following 1 Set the overrule period Temperature lock to 2 hours 2 Go to the room temperature home page Room 3 Press to select Result For the next 2 hours the room will NOT...

Страница 10: ...rol Leaving water temperature control means that you only control the leaving water temperature To control the leaving water temperature you can do the following You can Location Read out the desired...

Страница 11: ...Advice In order to avoid unsuccessful disinfection function at least allow the booster heater by the weekly program for minimum 4 hours starting from the scheduled start up of disinfection If the boos...

Страница 12: ...hot water and the DHW tank temperature decreases At 14 00 the DHW tank is programmed to heat up the water to a preset value example Storage eco 50 C Hot water is available again During the afternoon a...

Страница 13: ...e sufficient hot water comfortable You do NOT have to change the schedule easy You do NOT have to activate the DHW tank booster mode energy saving 4 5 6 Using the DHW tank booster mode About the DHW t...

Страница 14: ...ensure the heating cooling capacity of the system However during the afternoon the baby is sleeping and you want it to be quiet Then you can do the following Prerequisite You switched the permission...

Страница 15: ...during the winter You want to save energy but prevent your house from freezing Then you can do the following Prerequisite You switched the permission level to Advanced end user 1 Configure the holida...

Страница 16: ...pages that are possible for your system layout are listed 2 Select a home page and press 3 Do one of the following To display the home page select Yes and press To hide the home page select No and pre...

Страница 17: ...and press To program a schedule 1 Go to 7 3 User settings Set schedules 2 Open an empty predefined or user defined schedule 3 Change it 4 Save it Guidelines when programming 07 00 Set heating schedul...

Страница 18: ...6 Predefined schedules DHW tank temperature a Start production of domestic hot water Desired DHW tank temperature Preset value Storage comfort b Start production of domestic hot water Desired DHW tank...

Страница 19: ...igher than d as for low outdoor temperatures warmer water is required In cooling this value should be higher than d as for low outdoor temperatures less cold water suffices d Desired leaving water tem...

Страница 20: ...rs Version Energy metering Consumed elec Produced energy Error information Error history Contact helpdesk number Version User interface Indoor unit Outdoor unit User settings Display Temperature lock...

Страница 21: ...oling interruption will happen when selecting 6 0D 0 A 4 1 Domestic hot water Type Reheat only in case of a domestic hot water tank without an internal booster heater INFORMATION When the DHW tank boo...

Страница 22: ...58 Electricity 12 49 pence kWh 7 4 5 17 49 6 Energy saving tips Tips about room temperature Make sure the desired room temperature is NEVER too high in heating mode or too low in cooling mode but ALWA...

Страница 23: ...ion Error handling Error history 8 3 To check the warning history Prerequisite Only available if is displayed on the home pages 1 Go to 6 3 1 Information Error handling Warning history 8 4 Symptom You...

Страница 24: ...ving water temperature Water temperature at the water outlet of the heat pump Dealer Sales distributor for the product Authorized installer Technical skilled person who is qualified to install the pro...

Страница 25: ......

Страница 26: ......

Страница 27: ......

Страница 28: ...4P522035 1 2018 01 Copyright 2018 Daikin...

Отзывы: