Location

Adjust the preset value

 (Reheat).

Menu structure

See also:

"4.5.3 Scheduled mode" on page 12

"4.7 Preset values and schedules" on page 16

4.5.5

Using the DHW tank temperature home
page

Typical DHW tank temperature home pages

Depending on the user profile, the user interface gives you either a
basic  or  a  detailed  home  page.  The  examples  in  the  illustrations
below are in DHW tank mode = Scheduled.

User profile = Basic

User profile = Detailed

15:20

60°C

Storage comfort

Tank

Mon

15:20

60°C

00:00

Mon

Tue

Tank

Storage comfort

To read out and adjust the desired reheat temperature (in
scheduled and reheat mode)

1

Go  to  [7.4.3.3]: 

  >  User  settings  >  Preset  values  >  Tank

temperature > Reheat.

Result: 

You can read out the desired reheat temperature.

2

Press 

 or 

 to adjust.

To read out and overrule the active or next scheduled desired
temperature (in scheduled mode or sch reheat mode)

1

Go to the DHW tank temperature home page (Tank).

Result: 

60°C

 is displayed.

t

a

b

Tt

A1 A2

B1

B2

A1

A1 A2

B1

B2

A1

Tt

T

t

DHW tank temperature

t

Time

During period…

You can read out…

A1

The next scheduled action (

a

)

A2

The active action (

a

)

B1

The next scheduled action (

b

)

B2

The active action (

b

)

2

Press 

 or 

 to overrule. 

Note: 

If the desired temperature is

weather dependent, you cannot change it on the home page.

Usage example: You need more hot water than scheduled

If you are in the following situation:

▪ Current time = 10:30

▪ Next  scheduled  action  of  the  DHW  tank  =  Heat  up  to  the  preset

value (Eco; example: 55°C and sufficient for 2 persons) at 14:00

▪ This evening you need hot water for 3 persons

Then you can do the following:

1

Go to the DHW tank temperature home page (Tank).

2

Overrule  the  next  scheduled  action  by  changing  from  55°C  to
60°C.

Advantages:

▪ You will have sufficient hot water (= comfortable).

▪ You do NOT have to change the schedule (= easy).

▪ You  do  NOT  have  to  activate  the  DHW  tank  booster  mode

(= energy saving).

4.5.6

Using the DHW tank booster mode

About the DHW tank booster mode

You  can  use  the  DHW  tank  booster  mode  to  immediately  start
heating up the water to the preset value (Storage comfort). However,
this consumes extra energy.

To check if the DHW tank booster mode is active

1

Go to the DHW tank temperature home page (Tank).

2

Check the following:

▪ In  user  profile  =  Basic:  If    is  displayed,  the  DHW  tank

booster mode is active.

▪ In  user  profile  =  Detailed:  If    is  selected,  the  DHW  tank

booster mode is active.

To activate the DHW tank booster mode (user profile = Basic)

1

Go to the DHW tank temperature home page (Tank).

2

Press 

 for more than 5 seconds.

To activate the DHW tank booster mode (user profile = Detailed)

1

Go to the DHW tank temperature home page (Tank).

2

Press 

 to select  .

Usage example: You immediately need more hot water

If you are in the following situation:

▪ You already consumed most of your hot water.

▪ You  cannot  wait  for  the  next  scheduled  action  to  heat  up  the

DHW tank.

Then you can activate the DHW tank booster mode.

Advantage:  The  DHW  tank  immediately  starts  heating  up  the  water
to the preset value (Storage comfort).

INFORMATION

When  the  DHW  tank  booster  mode  is  active,  the  risk  of
space  heating/cooling  and  capacity  shortage  comfort
problems  is  significant.  In  case  of  frequent  domestic  hot
water  operation,  frequent  and  long  space  heating/cooling
interruptions will happen.

4.6

Advanced usage

4.6.1

About changing the user permission level

The  amount  of  information  you  can  read  out  in  the  menu  structure
depends on your user permission level:

▪ End user (= default)

▪ Adv. end user: You can read out more information.

To set the user permission level to Advanced end user

1

Go to the main menu or any of its submenus: 

.

2

Press 

 for more than 4 seconds.

Result: 

The  user  permission  level  switches  to  Adv.  end  user.

Additional information is displayed and "+" is added to the menu title.
The  user  permission  level  will  stay  in  Adv.  end  user  until  set
otherwise.

Содержание Altherma EBLQ016CAV3

Страница 1: ...English User reference guide Daikin Altherma low temperature monobloc EBLQ011CAV3 EBLQ014CAV3 EBLQ016CAV3 EBLQ011CAW1 EBLQ014CAW1 EBLQ016CAW1 EDLQ011CAV3 EDLQ014CAV3 EDLQ016CAV3 EDLQ011CAW1 EDLQ014CA...

Страница 2: ...g and programming schedules 16 4 7 3 Schedules Example 17 4 7 4 Predefined schedules Room temperature leaving water temperature main 18 4 7 5 Predefined schedules Leaving water temperature additional...

Страница 3: ...ive consequences for the environment and human health For more information contact your installer or local authority Batteries are marked with the following symbol This means that the batteries may NO...

Страница 4: ...Space heating cooling control How to control space heating cooling Setting the space operation mode Controlling the temperature Domestic hot water control How to control domestic hot water Reheat mode...

Страница 5: ...e User permission level Installer Defrost oil return mode is active Hot start mode is active Emergency operation is active 4 3 Basic usage 4 3 1 Using home pages About home pages You can use the home...

Страница 6: ...down a space You have to tell the system which space operation mode to use Heating only The system can heat up a space but NOT cool down a space You do NOT have to tell the system which space operatio...

Страница 7: ...water temperature control 3 Only for room thermostat control Go to the main leaving water temperature home page LWT main and check the following Is displayed next to the set point Then leaving water s...

Страница 8: ...The mode will return to Scheduled according to the overrule period Example Temporarily overruling the schedule AND changing the mode to preset value You have configured the following settings Setting...

Страница 9: ...3 hours Then you can do the following 1 Set the overrule period Temperature lock to 2 hours 2 Go to the room temperature home page Room 3 Press to select Result For the next 2 hours the room will NOT...

Страница 10: ...rol Leaving water temperature control means that you only control the leaving water temperature To control the leaving water temperature you can do the following You can Location Read out the desired...

Страница 11: ...Advice In order to avoid unsuccessful disinfection function at least allow the booster heater by the weekly program for minimum 4 hours starting from the scheduled start up of disinfection If the boos...

Страница 12: ...hot water and the DHW tank temperature decreases At 14 00 the DHW tank is programmed to heat up the water to a preset value example Storage eco 50 C Hot water is available again During the afternoon a...

Страница 13: ...e sufficient hot water comfortable You do NOT have to change the schedule easy You do NOT have to activate the DHW tank booster mode energy saving 4 5 6 Using the DHW tank booster mode About the DHW t...

Страница 14: ...ensure the heating cooling capacity of the system However during the afternoon the baby is sleeping and you want it to be quiet Then you can do the following Prerequisite You switched the permission...

Страница 15: ...during the winter You want to save energy but prevent your house from freezing Then you can do the following Prerequisite You switched the permission level to Advanced end user 1 Configure the holida...

Страница 16: ...pages that are possible for your system layout are listed 2 Select a home page and press 3 Do one of the following To display the home page select Yes and press To hide the home page select No and pre...

Страница 17: ...and press To program a schedule 1 Go to 7 3 User settings Set schedules 2 Open an empty predefined or user defined schedule 3 Change it 4 Save it Guidelines when programming 07 00 Set heating schedul...

Страница 18: ...6 Predefined schedules DHW tank temperature a Start production of domestic hot water Desired DHW tank temperature Preset value Storage comfort b Start production of domestic hot water Desired DHW tank...

Страница 19: ...igher than d as for low outdoor temperatures warmer water is required In cooling this value should be higher than d as for low outdoor temperatures less cold water suffices d Desired leaving water tem...

Страница 20: ...rs Version Energy metering Consumed elec Produced energy Error information Error history Contact helpdesk number Version User interface Indoor unit Outdoor unit User settings Display Temperature lock...

Страница 21: ...oling interruption will happen when selecting 6 0D 0 A 4 1 Domestic hot water Type Reheat only in case of a domestic hot water tank without an internal booster heater INFORMATION When the DHW tank boo...

Страница 22: ...58 Electricity 12 49 pence kWh 7 4 5 17 49 6 Energy saving tips Tips about room temperature Make sure the desired room temperature is NEVER too high in heating mode or too low in cooling mode but ALWA...

Страница 23: ...ion Error handling Error history 8 3 To check the warning history Prerequisite Only available if is displayed on the home pages 1 Go to 6 3 1 Information Error handling Warning history 8 4 Symptom You...

Страница 24: ...ving water temperature Water temperature at the water outlet of the heat pump Dealer Sales distributor for the product Authorized installer Technical skilled person who is qualified to install the pro...

Страница 25: ......

Страница 26: ......

Страница 27: ......

Страница 28: ...4P522035 1 2018 01 Copyright 2018 Daikin...

Отзывы: