4 Operation

User reference guide

10

EBLQ+EDLQ011~W1 + EK(2)CB

EKMB9W1

Daikin Altherma low temperature monobloc

4P522035-1 – 2018.01

2

Press 

 or 

 to adjust. 

Example: 

45°C 47°C

INFORMATION

In  case  of  weather  dependency,  an  offset  value  can  be
modified.

To adjust/overrule the leaving water temperature
(linked to room temperature setpoint)

INFORMATION

To see if the leaving water temperature setpoint is linked to
the  room  temperature  setpoint,  see 

"4.4.3  Determining

which temperature control you are using" on page 7

.

To set leaving water temperature preset values (main)

INFORMATION

You  cannot  adjust/overrule  the  leaving  water  temperature
(main)  for  room  thermostat  control  with  linked  leaving
water temperatures. However if necessary, you can adjust
the  desired  leaving  water  temperature  (main)  by  adjusting
preset values.

INFORMATION

Adjusting  the  leaving  water  temperature  is  permanent
unless  the  leaving  water  temperature  is  according  to  a
schedule. In that case the overruling is valid until the next
scheduled action.

1

Go to [7.4.2]: 

 > User settings > Preset values > LWT main.

2

Set the Preset values according to following graph.

Example: 

Room  thermostat  comfort  temperature  will  correspond

with leaving water comfort temperature.

Tl

Tr

▪ T

r

: Room temperature

▪ T

l

: Leaving water temperature

3

Press 

 or 

 to adjust/overrule.

To adjust the leaving water temperature (additional)

1

Go  to  the  additional  leaving  water  temperature  home  page
(LWT add).

2

Press 

 or 

 to adjust. 

Example: 

45°C 47°C

INFORMATION

In  case  of  weather  dependency,  an  offset  value  can  be
modified.

4.4.7

Leaving water temperature control -
About leaving water temperature control

Leaving  water  temperature  control  means  that  you  only  control  the
leaving water temperature. To control the leaving water temperature,
you can do the following:

You can…

Location

Read out

 the desired leaving water

temperature

 (main + additional).

Leaving water
temperature home
pages (main +
additional)

Adjust/overrule

 

the 

leaving 

water

temperature

 (main).

Adjust

  the  leaving  water 

temperature

(additional).

Select

 which leaving water temperature

schedule

 (main + additional) you want to

use.

Menu structure

Program 

leaving water temperature

schedule

 (main + additional).

Define preset values

 that are used by the

leaving water temperature schedule (main).

See also:

"4.4.6  Room  thermostat  control  -  Using  the  leaving  water
temperature home pages" on page 9

"4.7 Preset values and schedules" on page 16

4.4.8

Leaving water temperature control - Using
leaving water temperature control
according to a schedule

To set leaving water temperature preset values
(main)

INFORMATION

Adjusting  the  leaving  water  temperature  is  permanent
unless  the  leaving  water  temperature  is  according  to  a
schedule. In that case the overruling is valid until the next
scheduled action.

1

Go to [7.4.2]: 

 > User settings > Preset values > LWT main.

2

Press 

 or 

 to adjust. 

Example: 

35°C 37°C

To adjust the leaving water temperature
(additional)

1

Go  to  the  additional  leaving  water  temperature  home  page
(LWT add).

2

Press 

 or 

 to adjust. 

Example: 

45°C 47°C

INFORMATION

In  case  of  weather  dependency,  an  offset  value  can  be
modified.

4.4.9

Leaving water temperature control - Using
leaving water temperature control NOT
according to a schedule

To adjust the leaving water temperature (main)

1

Go  to  the  main  leaving  water  temperature  home  page  (LWT
main).

2

Press 

 or 

 to adjust. 

Example: 

35°C 37°C

To adjust the leaving water temperature
(additional)

1

Go  to  the  additional  leaving  water  temperature  home  page
(LWT add).

Содержание Altherma EBLQ016CAV3

Страница 1: ...English User reference guide Daikin Altherma low temperature monobloc EBLQ011CAV3 EBLQ014CAV3 EBLQ016CAV3 EBLQ011CAW1 EBLQ014CAW1 EBLQ016CAW1 EDLQ011CAV3 EDLQ014CAV3 EDLQ016CAV3 EDLQ011CAW1 EDLQ014CA...

Страница 2: ...g and programming schedules 16 4 7 3 Schedules Example 17 4 7 4 Predefined schedules Room temperature leaving water temperature main 18 4 7 5 Predefined schedules Leaving water temperature additional...

Страница 3: ...ive consequences for the environment and human health For more information contact your installer or local authority Batteries are marked with the following symbol This means that the batteries may NO...

Страница 4: ...Space heating cooling control How to control space heating cooling Setting the space operation mode Controlling the temperature Domestic hot water control How to control domestic hot water Reheat mode...

Страница 5: ...e User permission level Installer Defrost oil return mode is active Hot start mode is active Emergency operation is active 4 3 Basic usage 4 3 1 Using home pages About home pages You can use the home...

Страница 6: ...down a space You have to tell the system which space operation mode to use Heating only The system can heat up a space but NOT cool down a space You do NOT have to tell the system which space operatio...

Страница 7: ...water temperature control 3 Only for room thermostat control Go to the main leaving water temperature home page LWT main and check the following Is displayed next to the set point Then leaving water s...

Страница 8: ...The mode will return to Scheduled according to the overrule period Example Temporarily overruling the schedule AND changing the mode to preset value You have configured the following settings Setting...

Страница 9: ...3 hours Then you can do the following 1 Set the overrule period Temperature lock to 2 hours 2 Go to the room temperature home page Room 3 Press to select Result For the next 2 hours the room will NOT...

Страница 10: ...rol Leaving water temperature control means that you only control the leaving water temperature To control the leaving water temperature you can do the following You can Location Read out the desired...

Страница 11: ...Advice In order to avoid unsuccessful disinfection function at least allow the booster heater by the weekly program for minimum 4 hours starting from the scheduled start up of disinfection If the boos...

Страница 12: ...hot water and the DHW tank temperature decreases At 14 00 the DHW tank is programmed to heat up the water to a preset value example Storage eco 50 C Hot water is available again During the afternoon a...

Страница 13: ...e sufficient hot water comfortable You do NOT have to change the schedule easy You do NOT have to activate the DHW tank booster mode energy saving 4 5 6 Using the DHW tank booster mode About the DHW t...

Страница 14: ...ensure the heating cooling capacity of the system However during the afternoon the baby is sleeping and you want it to be quiet Then you can do the following Prerequisite You switched the permission...

Страница 15: ...during the winter You want to save energy but prevent your house from freezing Then you can do the following Prerequisite You switched the permission level to Advanced end user 1 Configure the holida...

Страница 16: ...pages that are possible for your system layout are listed 2 Select a home page and press 3 Do one of the following To display the home page select Yes and press To hide the home page select No and pre...

Страница 17: ...and press To program a schedule 1 Go to 7 3 User settings Set schedules 2 Open an empty predefined or user defined schedule 3 Change it 4 Save it Guidelines when programming 07 00 Set heating schedul...

Страница 18: ...6 Predefined schedules DHW tank temperature a Start production of domestic hot water Desired DHW tank temperature Preset value Storage comfort b Start production of domestic hot water Desired DHW tank...

Страница 19: ...igher than d as for low outdoor temperatures warmer water is required In cooling this value should be higher than d as for low outdoor temperatures less cold water suffices d Desired leaving water tem...

Страница 20: ...rs Version Energy metering Consumed elec Produced energy Error information Error history Contact helpdesk number Version User interface Indoor unit Outdoor unit User settings Display Temperature lock...

Страница 21: ...oling interruption will happen when selecting 6 0D 0 A 4 1 Domestic hot water Type Reheat only in case of a domestic hot water tank without an internal booster heater INFORMATION When the DHW tank boo...

Страница 22: ...58 Electricity 12 49 pence kWh 7 4 5 17 49 6 Energy saving tips Tips about room temperature Make sure the desired room temperature is NEVER too high in heating mode or too low in cooling mode but ALWA...

Страница 23: ...ion Error handling Error history 8 3 To check the warning history Prerequisite Only available if is displayed on the home pages 1 Go to 6 3 1 Information Error handling Warning history 8 4 Symptom You...

Страница 24: ...ving water temperature Water temperature at the water outlet of the heat pump Dealer Sales distributor for the product Authorized installer Technical skilled person who is qualified to install the pro...

Страница 25: ......

Страница 26: ......

Страница 27: ......

Страница 28: ...4P522035 1 2018 01 Copyright 2018 Daikin...

Отзывы: