Daikin Altherma 3 WS Скачать руководство пользователя страница 6

3 Operation

Operation manual

6

EWSAH/X06(U)DA9W

Daikin Altherma 3 WS

4P675761-2 – 2021.10

Explanation

a1

d

+

d

e

d

e

c

a2

b1

b2

Possible actions on this screen

Go through the list of the submenu.

Go to the submenu.

Adjust and automatically apply the desired
temperature.

Item

Description

Minimum temperature limit

a1

Fixed by the unit

a2

Restricted by the installer

Maximum temperature limit

b1

Fixed by the unit

b2

Restricted by the installer

Current temperature

c

Measured by the unit

Desired temperature

d

Turn the right dial to
increase/decrease.

Submenu

e

Turn or press the left dial to
go to the submenu.

3.2.4

Detailed screen with values

Example: 

a

b

c

a

b

c

7.2.1

Time/date

Hours

11

30

Minutes

a

Settings

b

Values

c

Selected setting and value

Possible actions on this screen

Go through the list of settings.

Change the value.

Go to the next setting.

Confirm changes and proceed.

3.3

Turning operation ON or OFF

3.3.1

Visual indication

Certain  functionalities  of  the  unit  can  be  enabled  or  disabled
separately.  If  a  functionality  is  disabled,  the  corresponding
temperature icon in the home screen will be greyed out.

Room temperature control

55

21

35

45

a

55

21

35

45

b

a

Room temperature control ON

b

Room temperature control OFF

Space heating/cooling operation

55

21

35

45

c

55

21

35

45

d

c

Space heating/cooling operation ON

d

Space heating/cooling operation OFF

Tank heating operation

55

21

35

45

e

55

21

35

45

f

e

Tank heating operation ON

f

Tank heating operation OFF

3.3.2

To turn ON or OFF

Room temperature control

1

Go to [C.1]: 

Operation

 > 

Room

.

Operation

Room

Space heating/cooling

On

On

C.1

2

Set operation to 

On

 or 

Off

.

Space heating/cooling operation

NOTICE

Room  frost  protection.

  Even  if  you  turn  OFF  space

heating/cooling  operation  ([C.2]: 

Operation

  > 

Space

heating/cooling

),  room  frost  protection  operation  –if

enabled–  can  still  activate.  However,  for  leaving  water
temperature  control  and  external  room  thermostat  control,
the protection is NOT guaranteed.

Содержание Altherma 3 WS

Страница 1: ...Operation manual Daikin Altherma 3 WS English Operation manual Daikin Altherma 3 WS EWSAH06DA9W EWSAH06UDA9W EWSAX06DA9W EWSAX06UDA9W...

Страница 2: ...ables If NOT request him to do so Keep the documentation for future reference Target audience End users Documentation set This document is part of a documentation set The complete set consists of Gene...

Страница 3: ...on 3 1 User interface Overview The user interface has the following components a b c a Status indicator b LCD screen c Dials and buttons Status indicator The LEDs of the status indicator light up or b...

Страница 4: ...een with schedule 3 2 1 Home screen Press the button to go back to the home screen You see an overview of the unit configuration and the room and setpoint temperatures Only symbols applicable for your...

Страница 5: ...ning Space heating cooling a Selected submenu Possible actions on this screen Go through the list Enter the submenu Enable disable breadcrumbs Submenu Description 0 or Malfunctioning Restriction Only...

Страница 6: ...3 3 Turning operation ON or OFF 3 3 1 Visual indication Certain functionalities of the unit can be enabled or disabled separately If a functionality is disabled the corresponding temperature icon in...

Страница 7: ...etween heating and cooling based on the outdoor temperature Restricted per month according to the Operation mode schedule 4 2 To restrict automatic changeover according to a schedule Conditions You se...

Страница 8: ...domestic water entering the DHW tank example 15 C At 00 00 the DHW tank is programmed to heat up the water to a preset value example Comfort 60 C During the morning you consume hot water and the DHW t...

Страница 9: ...e and proceed User pin code The User pin code is 0000 0000 User Advanced user pin code The Advanced user pin code is 1234 Additional menu items for the user are now visible 1234 Advanced user 3 7 Sche...

Страница 10: ...ogrammed action In this example Monday is the first day you programmed Thus the last programmed action is valid up to the first action of next Monday To copy the schedule to the other weekdays 1 Selec...

Страница 11: ...ename Select 3 optional To delete the current schedule name browse through the character list until is displayed then press to remove the previous character Repeat for each character of the schedule n...

Страница 12: ...D curve type 7 User settings Language Time date Holiday Quiet Electricity price Gas price 8 Information Energy data Malfunction history Dealer information Sensors Actuators Operation modes About Conne...

Страница 13: ...scheduled action Example When you have a party or when you are leaving for a couple of hours For longer periods You can use the holiday mode Tips about DHW tank temperature Use a weekly schedule for y...

Страница 14: ...cause Corrective action The desired room temperature is too low high Increase decrease the desired room temperature See 3 4 2 To change the desired room temperature 47 If the problem recurs daily do o...

Страница 15: ...mitters 2 If hydraulic balancing is not sufficient change the pump limitation settings 9 0D and 9 0E if applicable Various malfunctions Check if or is displayed on the home screen of the user interfac...

Страница 16: ...4P675761 2 2021 10 Copyright 2021 Daikin 4P675761 2 0000000V Verantwortung f r Energie und Umwelt...

Отзывы: