3 Operation

Operation manual

5

EWSAH/X06(U)DA9W
Daikin Altherma 3 WS
4P675761-2 – 2021.10

Item

Description

h Main zone

h1

Installed room thermostat type:

Unit operation is decided based on the ambient
temperature of the dedicated Human Comfort
Interface (BRC1HHDA used as room thermostat).

Unit operation is decided by the external room
thermostat (wired or wireless).

No room thermostat installed or set. Unit operation
is decided based on the leaving water temperature
regardless of the actual room temperature and/or
heating demand of the room.

h2

Installed heat emitter type:

Underfloor heating

Fancoil unit

Radiator

h3

21

Measured room temperature

(a)

h4

35

Leaving water temperature setpoint

(a)

i

Holiday mode

Holiday mode active

j

Additional zone

j1

Installed room thermostat type:

Unit operation is decided by the external room
thermostat (wired or wireless).

No room thermostat installed or set. Unit operation
is decided based on the leaving water temperature
regardless of the actual room temperature and/or
heating demand of the room.

j2

Installed heat emitter type:

Underfloor heating

Fancoil unit

Radiator

j3

45

Leaving water temperature setpoint

(a)

k Malfunction

A malfunction occurred.

See 

"6.1 To display the help text in case of a

malfunction"

 [

4

 14] for more information.

(a)

If the corresponding operation (for example: space heating) is not
active, the circle is greyed out.

3.2.2

Main menu screen

Starting from the home screen, press (

) or turn (

) the

left  dial  to  open  the  main  menu  screen.  From  the  main  menu,  you
can access the different setpoint screens and submenus.

a

2

Main zone

Additional zone

Room

Malfunctioning

Space heating/cooling

a

Selected submenu

Possible actions on this screen

Go through the list.

Enter the submenu.

Enable/disable breadcrumbs.

Submenu

Description

[0]

 or 

Malfunctioning

Restriction: 

Only displayed if a

malfunction occurs.

See 

"6.1 To display the help text in

case of a malfunction"

 [

4

 14] for more

information.

[1]

 

Room

Restriction: 

Only displayed if a

dedicated Human Comfort Interface
(BRC1HHDA used as room
thermostat) is controlling the indoor
unit.

Set the room temperature.

[2]

 

Main zone

Shows the applicable symbol for your
main zone emitter type.

Set the leaving water temperature for
the main zone.

[3]

 

Additional zone

Restriction: 

Only displayed if there

are two leaving water temperature
zones. Shows the applicable symbol
for your additional zone emitter type.

Set the leaving water temperature for
the additional zone (if present).

[4]

 

Space heating/

cooling

Shows the applicable symbol of your
unit.

Put the unit in heating mode or cooling
mode. You cannot change the mode
on heating only models.

[5]

 

Tank

Set the domestic hot water tank
temperature.

[7]

 

User settings

Gives access to user settings such as
holiday mode and quiet mode.

[8]

 

Information

Displays data and information about
the indoor unit.

[9]

 

Installer

settings

Restriction: 

Only for the installer.

Gives access to advanced settings.

[A]

 

Commissioning

Restriction: 

Only for the installer.

Perform tests and maintenance.

[B]

 

User profile

Change the active user profile.

[C]

 

Operation

Turn heating/cooling functionality and
domestic hot water preparation on or
off.

3.2.3

Setpoint screen

The  setpoint  screen  is  displayed  for  screens  describing  system
components that need a setpoint value.

Examples

[1] Room temperature screen

+

21

°C

1

Room

[2] Main zone screen

+

35

°C

2

Main zone

[3] Additional zone screen

+

45

°C

3

Additional zone

[5] Tank temperature screen

+

50

°C

5

Tank

Содержание Altherma 3 WS

Страница 1: ...Operation manual Daikin Altherma 3 WS English Operation manual Daikin Altherma 3 WS EWSAH06DA9W EWSAH06UDA9W EWSAX06DA9W EWSAX06UDA9W...

Страница 2: ...ables If NOT request him to do so Keep the documentation for future reference Target audience End users Documentation set This document is part of a documentation set The complete set consists of Gene...

Страница 3: ...on 3 1 User interface Overview The user interface has the following components a b c a Status indicator b LCD screen c Dials and buttons Status indicator The LEDs of the status indicator light up or b...

Страница 4: ...een with schedule 3 2 1 Home screen Press the button to go back to the home screen You see an overview of the unit configuration and the room and setpoint temperatures Only symbols applicable for your...

Страница 5: ...ning Space heating cooling a Selected submenu Possible actions on this screen Go through the list Enter the submenu Enable disable breadcrumbs Submenu Description 0 or Malfunctioning Restriction Only...

Страница 6: ...3 3 Turning operation ON or OFF 3 3 1 Visual indication Certain functionalities of the unit can be enabled or disabled separately If a functionality is disabled the corresponding temperature icon in...

Страница 7: ...etween heating and cooling based on the outdoor temperature Restricted per month according to the Operation mode schedule 4 2 To restrict automatic changeover according to a schedule Conditions You se...

Страница 8: ...domestic water entering the DHW tank example 15 C At 00 00 the DHW tank is programmed to heat up the water to a preset value example Comfort 60 C During the morning you consume hot water and the DHW t...

Страница 9: ...e and proceed User pin code The User pin code is 0000 0000 User Advanced user pin code The Advanced user pin code is 1234 Additional menu items for the user are now visible 1234 Advanced user 3 7 Sche...

Страница 10: ...ogrammed action In this example Monday is the first day you programmed Thus the last programmed action is valid up to the first action of next Monday To copy the schedule to the other weekdays 1 Selec...

Страница 11: ...ename Select 3 optional To delete the current schedule name browse through the character list until is displayed then press to remove the previous character Repeat for each character of the schedule n...

Страница 12: ...D curve type 7 User settings Language Time date Holiday Quiet Electricity price Gas price 8 Information Energy data Malfunction history Dealer information Sensors Actuators Operation modes About Conne...

Страница 13: ...scheduled action Example When you have a party or when you are leaving for a couple of hours For longer periods You can use the holiday mode Tips about DHW tank temperature Use a weekly schedule for y...

Страница 14: ...cause Corrective action The desired room temperature is too low high Increase decrease the desired room temperature See 3 4 2 To change the desired room temperature 47 If the problem recurs daily do o...

Страница 15: ...mitters 2 If hydraulic balancing is not sufficient change the pump limitation settings 9 0D and 9 0E if applicable Various malfunctions Check if or is displayed on the home screen of the user interfac...