9
|
Electrical installation
Installer reference guide
119
ERGA04~08EA + EHBH/X04+08EF
Daikin Altherma 3 R W
4P629085-1B – 2021.11
In case of…
See…
Wired room thermostat with
multi-zoning base unit
▪
Installation manual of the wired room
thermostat (digital or analogue) + multi-zoning
base unit
▪
Addendum book for optional equipment
▪
In this case:
-
You need to connect the wired room
thermostat (digital or analogue) to the
multi-zoning base unit
-
You need to connect the multi-zoning base
unit to the outdoor unit
-
For cooling/heating operation, you also
need to implement a relay (field supply, see
addendum book for optional equipment)
9.3.1 To connect the main power supply
1
Open the following (see
"7.2.4 To open the indoor unit"
1
Front panel
1
2
3
2
Switch box cover
3
Switch box
2
Connect the main power supply.
In case of normal kWh rate power supply
Interconnection cable
(= main power supply)
Wires: (3+GND)×1.5 mm²
—
B
C
A
A
a
1 2 3