Operation

User reference guide

37

EBBH/X11+16D + EBVH/X11+16S(U)18+23D
Daikin Altherma 3 R F+W
4P643607-1B – 2022.08

3

Select 

Select

.

Delete

Rename

Select

4

Select the schedule that you currently want to use.

Possible schedules

The table contains the following information:

Schedule/Control

: This column shows you where you can consult the currently

selected schedule for the specific control. If needed, you can:

-

Select another schedule. See 

"To select which schedule you currently want to

use"

 [

4

 36].

-

Program your own schedule. See 

"5.8.3 Schedule screen: Example"

 [

4

 39].

Predefined schedules

: Number of available predefined schedules in the system

for the specific control.

 

If needed, you can program your own schedule.

Activation screen

: For most controls, a schedule is only effective if it activated in

its corresponding activation screen. This entry shows you where to activate it.

Possible actions

: Actions you can use when programming a schedule. For most

schedules, you can program up to 6 actions per day.

Schedule/Control

Description

[1.2] 

Room

 > 

Heating

schedule

Schedule for the desired room
temperature in heating mode.

Predefined schedules:

 3

Activation screen

: [1.1] 

Schedule

Possible actions

: Temperatures within range.

[1.3] 

Room

 > 

Cooling

schedule

Schedule for the desired room
temperature in cooling mode.

Predefined schedules:

 1

Activation screen

: [1.1] 

Schedule

Possible actions

: Temperatures within range.

[2.2] 

Main zone

 > 

Heating

schedule

Schedule for the desired leaving
water temperature for the
main zone in heating mode.

Predefined schedules:

 3

Activation screen

: [2.1] 

Schedule

Possible actions

:

In 

case 

of 

weather-dependent: 

Shift

temperatures within range.

Otherwise: Temperatures within range

[2.3] 

Main zone

 > 

Cooling

schedule

Schedule for the desired leaving
water temperature for the
main zone in cooling mode.

Predefined schedules:

 1

Activation screen

: [2.1] 

Schedule

Possible actions

:

In 

case 

of 

weather-dependent: 

Shift

temperatures within range.

Otherwise: Temperatures within range

Содержание Altherma 3 R F+W EBBH11D 6V Series

Страница 1: ...1D 6V EBBH11D 9W EBBH16D 6V EBBH16D 9W EBBX11D 6V EBBX11D 9W EBBX16D 6V EBBX16D 9W EBVH11S18 23D 6V EBVH11S18 23D 9W EBVH16S18 23D 6V EBVH16S18 23D 9W EBVH16SU23D 6V EBVX11S18 23D 6V EBVX11S18 23D 9W...

Страница 2: ...5 6 4 To change the desired room temperature 29 5 6 5 To change the desired leaving water temperature 30 5 7 Domestic hot water control 31 5 7 1 About domestic hot water control 31 5 7 2 Reheat mode 3...

Страница 3: ...rma 3 R F W 4P643607 1B 2022 08 8 6 Symptom The system is making gurgling noises after commissioning 60 9 Relocation 62 9 1 Overview Relocation 62 10 Disposal 63 11 Glossary 64 12 Installer settings T...

Страница 4: ...n the box of the indoor unit User reference guide Detailed step by step instructions and background information for basic and advanced usage Format Digital files on https www daikin eu Use the search...

Страница 5: ...help button The breadcrumbs appear in the top left corner of the screen 2 To disable the breadcrumbs Press the help button again This document also mentions these breadcrumbs Example 1 Go to 4 3 Spac...

Страница 6: ...es a situation that could result in equipment or property damage INFORMATION Indicates useful tips or additional information Symbols used on the unit Symbol Explanation Before installation read the in...

Страница 7: ...educed physical sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the h...

Страница 8: ...NOT be mixed with unsorted household waste If a chemical symbol is printed beneath the symbol this chemical symbol means that the battery contains a heavy metal above a certain concentration Possible...

Страница 9: ...entilate the room and contact the dealer where you purchased the unit Do NOT use the unit until a service person confirms that the part from which the refrigerant leaked has been repaired WARNING Air...

Страница 10: ...he main zone can only provide refreshment Real cooling is then NOT allowed 3 1 Components in a typical system layout g A d b a f e c B C A Main zone Example Living room B Additional zone Example Bedro...

Страница 11: ...se through the list of digits and change the selected digit Move the cursor from left to right Confirm the pin code and proceed User pin code The User pin code is 0000 0000 User Advanced user pin code...

Страница 12: ...temperature control you can use the room temperature setpoint screen to read out and adjust the desired room temperature 1 Go to 1 Room Room 1 2 Adjust the desired room temperature 21 C 1 a b Room a...

Страница 13: ...curve Additional zone Cooling 3 6 Additional zone Cooling WD curve 2 Change the weather dependent curve There are 2 types of WD curves slope offset curve default and 2 points curve If needed you can...

Страница 14: ...d set offset Confirm changes and return to the submenu 2 points curve Y1 Y2 X1 X2 X1 X2 Outdoor ambient temperature Y1 Y2 Desired leaving water temperature Possible actions on this screen Go through t...

Страница 15: ...perature setpoint screen to read out and adjust the domestic hot water temperature 1 Go to 5 Tank Tank 5 2 Adjust the domestic hot water temperature 50 C 5 a b Tank a Actual domestic hot water tempera...

Страница 16: ...e User reference guide 16 EBBH X11 16D EBVH X11 16S U 18 23D Daikin Altherma 3 R F W 4P643607 1B 2022 08 5 4 Turning operation ON or OFF 425 5 7 Domestic hot water control 431 5 8 Preset values and sc...

Страница 17: ...ator light up or blink to show the operating mode of the unit LED Mode Description Blinking blue Standby The unit is not in operation Continuous blue Operation The unit is in operation Blinking red Ma...

Страница 18: ...onfirm your choice or go to a submenu b Back button Press to go back 1 step in the menu structure c Home button Press to go back to the home screen d Help button Press to show a help text related to t...

Страница 19: ...etpoint 1 5 Setpoint range Heating minimum Heating maximum Cooling minimum Cooling maximum 7 2 Time date Hours Minutes Year Month Day Daylight savings time Format 7 3 Holiday Activation From Till 7 4...

Страница 20: ...Screen with weather dependent curve c4 Screen with schedule 5 3 1 Home screen Press the button to go back to the home screen You see an overview of the unit configuration and the room and setpoint tem...

Страница 21: ...or heat pump is forced off d Current date and time e Smart energy e1 Smart energy is available via solar panels or smart grid e2 Smart energy is currently being used for space heating e3 Smart energy...

Страница 22: ...e Underfloor heating Fancoil unit Radiator i3 21 Measured room temperature a i4 35 Leaving water temperature setpoint a j Holiday mode Holiday mode active k Additional zone k1 Installed room thermosta...

Страница 23: ...Human Comfort Interface BRC1HHDA used as room thermostat is controlling the indoor unit Set the room temperature 2 Main zone Shows the applicable symbol for your main zone emitter type Set the leaving...

Страница 24: ...onfiguring the ONECTA app 5 3 3 Setpoint screen The setpoint screen is displayed for screens describing system components that need a setpoint value Examples 1 Room temperature screen 21 C 1 Room 2 Ma...

Страница 25: ...ours 11 30 Minutes a Settings b Values c Selected setting and value Possible actions on this screen Go through the list of settings Change the value Go to the next setting Confirm changes and proceed...

Страница 26: ...activate However for leaving water temperature control and external room thermostat control the protection is NOT guaranteed 1 Go to C 2 Operation Space heating cooling Operation Space heating coolin...

Страница 27: ...and WLAN 8 9 Running hours Running hours of specific system components 5 6 Space heating cooling control 5 6 1 About space heating cooling control Controlling space heating cooling typically consists...

Страница 28: ...he status indicator will show a blue pulsation with an interval of approximately 5 seconds While the unit is in operation the status indicator will light up blue constantly To set the space operation...

Страница 29: ...ture control you are using 6 1 6 bar 22 19 55 21 35 45 a2 a1 b 18 Feb 2018 a1 Heat emitter of the main zone in this example Underfloor heating a2 Heat emitter of the additional zone in this example Ra...

Страница 30: ...occurs You can avoid scheduled behaviour by temporarily turning off scheduling To turn off room temperature scheduling 1 Go to 1 1 Room Schedule 2 Select No 5 6 5 To change the desired leaving water t...

Страница 31: ...one of the following 2 1 Main zone Schedule 3 1 Additional zone Schedule 2 Select No To enable weather dependent operation for the leaving water temperature See 5 9 4 Using weather dependent curves 44...

Страница 32: ...or the tank the tank temperature is determined automatically by the outdoor temperature For more information see 5 9 Weather dependent curve 445 To determine which domestic hot water mode you are usin...

Страница 33: ...tions it is recommended to switch to one of the following modes Schedule only Schedule reheat 5 7 3 Scheduled mode In scheduled mode the DHW tank produces hot water corresponding to a schedule The bes...

Страница 34: ...1 2 4 5 3 Tt Domestic hot water tank temperature t Time 5 7 5 To change the domestic hot water temperature In Reheat only mode you can use the tank temperature setpoint screen to read out and adjust t...

Страница 35: ...e water to the Comfort temperature INFORMATION When powerful operation is active the risk of space heating cooling and capacity shortage comfort problems is significant In case of frequent domestic ho...

Страница 36: ...ur system layout and installer configuration schedules for multiple controls may be available You can See Set if a specific control needs to act according to a schedule Activation screen in Possible s...

Страница 37: ...ions Actions you can use when programming a schedule For most schedules you can program up to 6 actions per day Schedule Control Description 1 2 Room Heating schedule Schedule for the desired room tem...

Страница 38: ...zone On When the system is allowed to cool down the additional zone 4 2 Space heating cooling Operation mode schedule Schedule per month for when to operate the unit in heating mode and when in coolin...

Страница 39: ...values High Medium Low See 5 8 4 Setting the energy prices 443 Restriction Only available to installers 9 4 2 Installer settings Booster heater BSH allowance schedule Predefined schedules 1 Activatio...

Страница 40: ...unday 6 Give the schedule a name To go to the schedule 1 Go to 1 1 Room Schedule 2 Set scheduling to Yes 3 Go to 1 2 Room Heating schedule To clear the content of the week schedule 1 Select the name o...

Страница 41: ...colour than a low temperature 0 6 00 8 30 17 30 20 C 18 C 22 00 18 C 21 C 12 24 Mon Note To clear an action set its time as the time of the previous action 4 Confirm the changes Result The schedule fo...

Страница 42: ...un User defined 1 C 5 Repeat this action for all other weekdays Mon Sat Wed Fri Thu Tue Sun User defined 1 C To program the schedule for Saturday and copy it to Sunday 1 Select Saturday 2 Select Edit...

Страница 43: ...characters 5 Confirm the new name INFORMATION Not all schedules can be renamed Usage example You work in a 3 shift system If you work in a 3 shift system you can do the following 1 Program 3 room tem...

Страница 44: ...electricity supplier 3 Confirm the changes INFORMATION The values correspond with the electricity price values for High Medium and Low previously set If no schedule is set the electricity price for Hi...

Страница 45: ...operates weather dependent if the desired leaving water or tank temperature is determined automatically by the outdoor temperature It therefore is connected to a temperature sensor on the North wall o...

Страница 46: ...ee 5 9 4 Using weather dependent curves 448 Availability The weather dependent curve is available for Main zone Heating Main zone Cooling Additional zone Heating Additional zone Cooling Tank only avai...

Страница 47: ...nd offset Define the weather dependent curve by its slope and offset Change the slope to differently increase or decrease the temperature of the leaving water for different ambient temperatures For ex...

Страница 48: ...one heating Main zone or additional zone cooling Domestic hot water X1 X2 Examples of outdoor ambient temperature Y1 Y2 Y3 Y4 Examples of desired tank temperature or leaving water temperature The icon...

Страница 49: ...ge the type for all zones main additional and for the tank go to 2 E Main zone WD curve type Viewing which type is selected is also possible via 3 C Additional zone WD curve type 5 E Tank WD curve typ...

Страница 50: ...oor temperatures Slope Offset OK Cold OK Hot Cold OK Cold Cold Cold Hot Hot OK Hot Cold Hot Hot To fine tune the weather dependent curve 2 points curve The following table describes how to fine tune t...

Страница 51: ...ive To program a quiet mode schedule Restriction Only possible if enabled by the installer 1 Go to 7 4 2 User settings Quiet Schedule 2 Program the schedule Possible actions You can use the following...

Страница 52: ...es 3 Set the last day of your holiday Go to 7 3 3 Till Select a date Confirm the changes 5 10 4 Using WLAN INFORMATION Restriction WLAN settings are only visible when a WLAN cartridge or WLAN module i...

Страница 53: ...ile doing this the following actions and information are needed on the user interface D Wireless gateway Malfunctioning Operation User profile Room D Wireless gateway D 1 Mode D 2 Reboot D 3 WPS D 4 R...

Страница 54: ...cloud 2 In the Remove from cloud screen select Yes D 5 Home network connection Read out the status of the connection to the home network 1 Go to D 5 Wireless gateway Home network connection 2 Read ou...

Страница 55: ...when you are leaving for a couple of hours For longer periods You can use the holiday mode Tips about leaving water temperature In heating mode a lower desired leaving water temperature results in low...

Страница 56: ...ur installer for more information WARNING MILDLY FLAMMABLE MATERIAL The refrigerant inside this unit is mildly flammable WARNING The refrigerant inside the unit is mildly flammable but normally does N...

Страница 57: ...8 NOTICE Applicable legislation on fluorinated greenhouse gases requires that the refrigerant charge of the unit is indicated both in weight and CO2 equivalent Formula to calculate the quantity in CO2...

Страница 58: ...case of a malfunction the following will appear on the home screen depending on the severity Error Malfunction You can get a short and a long description of the malfunction as follows 1 Press the lef...

Страница 59: ...heat emitter type See 5 6 5 To change the desired leaving water temperature 430 The weather dependent curve is set incorrectly Adjust the weather dependent curve See 5 9 Weather dependent curve 445 8...

Страница 60: ...cy is set to auto SH reduced DHW on space heating is reduced but domestic hot water is still available auto SH reduced DHW off space heating is reduced and domestic hot water is NOT available auto SH...

Страница 61: ...ith the air purge function of the unit to be performed by the installer If you purge air from the heat emitters or collectors mind the following WARNING Air purging heat emitters or collectors Before...

Страница 62: ...18 23D Daikin Altherma 3 R F W 4P643607 1B 2022 08 9 Relocation 9 1 Overview Relocation If you want to relocate parts of your system contact your installer You can find the contact helpdesk number vi...

Страница 63: ...W 4P643607 1B 2022 08 10 Disposal NOTICE Do NOT try to dismantle the system yourself dismantling of the system treatment of the refrigerant oil and other parts MUST comply with applicable legislation...

Страница 64: ...r domain Service company Qualified company which can perform or coordinate the required service to the product Installation manual Instruction manual specified for a certain product or application exp...

Страница 65: ...ckup heater type 9 3 1 read only Domestic hot water 9 2 1 Emergency 9 5 Number of zones 4 4 Booster heater capacity 9 4 1 if applicable Backup heater Voltage 9 3 2 Configuration 9 3 3 Capacity step 1...

Страница 66: ...erma 3 R F W 4P643607 1B 2022 08 Setting Fill in Heat up mode 5 6 Comfort setpoint 5 2 Eco setpoint 5 3 Reheat setpoint 5 4 Setpoint mode 5 B WD curve type 5 E read only 12 2 Settings menu Setting Fil...

Страница 67: ......

Страница 68: ...4P643607 1B 2022 08 Copyright 2021 Daikin Verantwortung f r Energie und Umwelt...

Отзывы: