4 Installation
Installation manual
6
EABH/9W
Daikin Altherma 3 H W
4P644479-1 – 2020.12
NOTICE
More technical specifications of the different connections
are indicated on the inside of the indoor unit.
Backup heater
type
Power supply
Required number of
conductors
*6V
1N~ 230 V (6V)
2+GND
3~ 230 V (6T1)
3+GND
*9W
3N~ 400 V
4+GND
4
Installation
4.1
Opening the units
4.1.1
To open the indoor unit
Overview
1
2
3
1
4
4
1
Front panel
2
Switch box cover
3
Switch box
4
User interface panel
Open
1
Remove the front panel.
2
2
1
3
2
If you have to connect electrical wiring, remove the switch box
cover.
4×
3
If you have to do work behind the switch box, open the switch
box.
2×
1
2
4
If you have to do work behind the user interface panel or upload
new software into the user interface, open the user interface
panel.
1
2
3
2×
5
Optional: Remove the user interface panel.
NOTICE
If you remove the user interface panel, also disconnect the
cables from the back of the user interface panel to prevent
damage.