background image

3 Operation

Operation manual

7

EGSAH/X06+10DA9W(G)
Daikin Altherma 3 GEO
4P569812-1 – 2019.02

To check if powerful operation is active

If 

 is displayed on the home screen, powerful operation is active.

Activate or deactivate 

Powerful operation

 as follows:

1

Go to [5.1]: 

Tank

 > 

Powerful operation

2

Turn powerful operation 

Off

 or 

On

.

Usage example: You immediately need more hot water

You are in the following situation:

▪ You already consumed most of your domestic hot water.

▪ You  cannot  wait  for  the  next  scheduled  action  to  heat  up  the

domestic hot water tank.

Then  you  can  activate  powerful  operation.  The  domestic  hot  water
tank will start heating up the water to the 

Comfort

 temperature.

3.5

Advanced usage

The  amount  of  information  you  can  read  out  in  the  menu  structure
depends on your user permission level:

User

: Standard mode

Advanced user

: You can read out more information

To change the user permission level

You can change the user permission level as follows:

1

Go to [B]: 

User profile

.

2

Enter the applicable code for the user permission.

▪ Move the cursor from left to right.

▪ Browse  through  the  list  of  digits  and  change  the

selected digit.

▪ Confirm the pincode and proceed.

User pin code

The 

User

 pin code is 

0000

.

Advanced user pin code

The 

Advanced user

 pin code is 

1234

. Additional menu items for the

user are now visible.

3.6

Schedule screen: Example

This  example  shows  how  to  set  a  room  temperature  schedule  in
heating mode for the main zone.

INFORMATION

The procedures to program other schedules are similar.

To program the schedule

Example: 

You want to program the following schedule:

Mon

Sat

Wed

Fri

Thu

Tue

Sun

User defined 1

Prerequisite: 

The  room  temperature  schedule  is  only  available  if

room  thermostat  control  is  active.  If  leaving  water  temperature
control is active, you can program the main zone schedule instead.

1

Go to the schedule.

2

(optional) Clear the content of the whole week schedule or the
content of a selected day schedule.

3

Program the schedule for 

Monday

.

4

Copy the schedule to the other weekdays.

5

Program the schedule for 

Saturday

 and copy it to 

Sunday

.

6

Give the schedule a name.

To go to the schedule:

1

Go to [1.1]: 

Room

 > 

Schedule

.

2

Set scheduling to 

Yes

.

3

Go to [1.2]: 

Room

 > 

Heating schedule

.

To clear the content of the week schedule:

1

Select the name of the current schedule.

Mon

Sat

Wed

Fri

Thu

Tue

Sun

User defined 1

2

Select 

Delete

.

Delete

Rename

Select

3

Select 

OK

 to confirm.

To clear the content of a day schedule:

1

Select the day of which you want to clear the
content. For example 

Friday

Mon

Sat

Wed

Fri

Thu

Tue

Sun

User defined 1

C

2

Select 

Delete

.

Delete

Edit

Copy

3

Select 

OK

 to confirm.

To program the schedule for Monday:

1

Select 

Monday

.

Mon

Sat

Wed

Fri

Thu

Tue

Sun

User defined 1

2

Select 

Edit

.

Delete

Edit

Copy

Содержание Altherma 3 GEO EGSAH06DA9W

Страница 1: ...Operation manual Daikin Altherma 3 GEO English Operation manual Daikin Altherma 3 GEO EGSAH06DA9W EGSAH10DA9W EGSAX06DA9W G EGSAX10DA9W G ...

Страница 2: ...eep the documentation for future reference Target audience End users Documentation set This document is part of a documentation set The complete set consists of General safety precautions Safety instructions that you must read before installing Format Paper in the box of the unit Operation manual Quick guide for basic usage Format Paper in the box of the unit User reference guide Detailed step by ...

Страница 3: ...icator b LCD screen c Dials and buttons Status indicator The LEDs of the status indicator light up or blink to show the operating mode of the unit LED Mode Description Blinking blue Standby The unit is not in operation Continuous blue Operation The unit is in operation Blinking red Malfunction A malfunction occurred See 6 1 To display the help text in case of a malfunction on page 11 for more info...

Страница 4: ...5 Measured tank temperature 1 b Current date and time c Disinfection Powerful Disinfection mode active Powerful operation mode active d Space operation mode Cooling Heating e Outdoor quiet mode e1 6 Measured outdoor temperature 1 e2 Quiet mode active e3 Outdoor brine piping f Indoor unit domestic hot water tank f1 Floor standing indoor unit with integrated tank f2 Water pressure g Main zone g1 Ins...

Страница 5: ...de or cooling mode Tank Set the domestic hot water tank temperature User settings Gives access to user settings such as holiday mode and quiet mode Information Displays data and information about the indoor unit Installer settings Restriction Only for the installer Gives access to advanced settings Commissioning Restriction Only for the installer Perform tests and maintenance User profile Change t...

Страница 6: ...r temperature is set by your installer in accordance with the heat emitter type Only adjust the leaving water temperature settings in case of problems You can use the leaving water temperature setpoint screen to read out and adjust the desired leaving water temperature 1 Go to 2 Main zone or 3 Additional zone You can read out the desired and actual leaving water temperature in the center of the se...

Страница 7: ...ditional menu items for the user are now visible 3 6 Schedule screen Example This example shows how to set a room temperature schedule in heating mode for the main zone INFORMATION The procedures to program other schedules are similar To program the schedule Example You want to program the following schedule Mon Sat Wed Fri Thu Tue Sun User defined 1 Prerequisite The room temperature schedule is o...

Страница 8: ...ue Sun User defined 1 C 4 Select Paste Delete Edit Copy Paste Result Mon Sat Wed Fri Thu Tue Sun User defined 1 C 5 Repeat this action for all other weekdays Mon Sat Wed Fri Thu Tue Sun User defined 1 C To program the schedule for Saturday and copy it to Sunday 1 Select Saturday 2 Select Edit 3 Use the left dial to select an entry and edit the entry with the right dial 0 8 00 23 00 21 C 18 C 12 24...

Страница 9: ...g Operation mode Operation mode schedule 5 Tank Powerful operation Comfort setpoint Eco setpoint Reheat setpoint Schedule WD curve type 7 User settings Language Time date Holiday Quiet Electricity price Gas price 8 Information Energy data Malfunction history Dealer information Sensors Actuators Operation modes About Connection status Running hours B User profile C Operation Room Space heating cool...

Страница 10: ...e Example When you have a party or when you are leaving for a couple of hours For longer periods You can use the holiday mode Example When you stay at home during your holiday or when you go away during your holiday Tips about DHW tank temperature Use a weekly schedule for your normal domestic hot water needs only in scheduled mode Program to heat up the DHW tank to a preset value Comfort higher D...

Страница 11: ...e 6 Possible cause Corrective action The weather dependent curve is set incorrectly Adjust the weather dependent curve See the user reference guide 6 3 Symptom The water at the tap is too cold Possible cause Corrective action You ran out of domestic hot water because of unusual high consumption If you immediately need domestic hot water activate the DHW tank Powerful operation However this consume...

Страница 12: ... collectors check if or is displayed on the home screen of the user interface If not you can purge air immediately If yes make sure that the room where you want to purge air is sufficiently ventilated Reason Refrigerant might leak into the water circuit and subsequently into the room when you purge air from the heat emitters or collectors 7 Disposal NOTICE Do NOT try to dismantle the system yourse...