![Daikin AHT VENTO GREEN MC Скачать руководство пользователя страница 44](http://html.mh-extra.com/html/daikin/aht-vento-green-mc/aht-vento-green-mc_operating-instructions-manual_501747044.webp)
10 | Operation
AHT Cooling Systems GmbH | en
44 / 671
369779_1_1019
10 Operation
Only trained operating personnel may operate the ap-
pliance.
WARNING
Damage to the electrical system and/or
the refrigerant circuit.
Contact with live parts may result in electric
shock. Flammable refrigerant can escape and
cause an explosive gas/air mixture. Fire haz-
ard due to sparking or overload.
▪ Do not allow external forces to act on the
appliance, e.g. careless handling with a lift
truck or floor cleaning machine.
▪ Avoid transmitting pulsations and vibra-
tions to the appliance.
▪ Observe safety notices and warnings for
appliances with flammable refrigerants
(see →Flammable refrigerants).
▪ If the appliance is damaged or the fuse is
tripped:
1. Disconnect the appliance.
2. Secure the appliance against reconnec-
tion.
3. Contact the maintenance service (see
→Maintenance services).
CAUTION
Risk of glass breakage.
Body cuts. Impact injury
▪ Check that glass doors are closed. Ensure
free passageways when glass doors are
open.
▪ Do not load glass doors.
▪ Do not strike glass elements with movable
objects (shopping trolleys, pallet trucks, ...).
▪ Check glass elements for damage, e.g.
cracks, breaks. In the event of damage,
promptly contact the maintenance service
(see →Maintenance services).
▪ Close glass door immediately and com-
pletely after loading.
▪ Check for breakage of stored glass con-
tainers.
▪ Hinges on glass doors must be fixed and
mounted with a cover. In the event of any
deviations, contact the maintenance ser-
vice (see → Maintenance services).
Breakage of glass containers.
Hand and body cuts.
▪ Use protective gloves to remove split glass
parts and goods that may have been dam-
aged as a result.
▪ Carefully and completely remove all split
glass parts and damaged goods.
Dispose of broken glass.
Hand cuts.
▪ Use protective gloves to remove split glass
parts and goods that may have been dam-
aged as a result.
▪ Carefully and completely remove all split
glass parts and damaged goods.
NOTICE
Material damage due to misuse.
Operate the appliance in a stable operating
position (horizontal alignment).
Operate the device only on the designated
adjustable feet.
▪ Check that the appliance is in good, proper condi-
tion. Any damage must be repaired immediately.
Property damage due to misuse.
▪ Do not operate the appliance above the climate
class
stated on the rating plate (see →Rating plate
and serial number) or on the additional stickers.
▪ The ambient temperature must not fall below 16°C
(60.8°F).
▪ Observe the prescribed storage temperature of the
stored products.
▪ Check the interior temperature (see →Tempera-
ture display).
▪ In the event of a power failure, stored goods must
be checked by the operating company (tempera-
ture check).
▪ Check the area in which goods are placed for for-
eign objects.
▪ Remove goods stored incorrectly immediately.
▪ Remove food and packaging residues (see →
Basic cleaning).
▪ Make sure the doors are closed.
For special climatic conditions with high humidity, con-
densation (condensation water) may form inside the
appliance or occur on the air outlets at the top. This
condensation must be removed for hygienic reasons.
WARNING
Electrostatic discharge and spark for-
mation with flammable refrigerant.
On a damaged / leaking refrigerant circuit,
sparks may ignite escaping refrigerant. Fire
hazard.
▪ Use a damp cloth or sponge to remove
condensation water.
▪ Do not use dry cloths or sponges to dry
the appliance.
CAUTION
Leakage of liquids from damaged
packaging. Drainage of condensation
from doors.
Slipping hazard.
▪ Check for puddles in front of and under the
appliance.
▪ Remove spilled fluids/condensation imme-
diately.
Содержание AHT VENTO GREEN MC
Страница 27: ...de AHT Cooling Systems GmbH 369779_1_1019 27 671 ...
Страница 51: ...en AHT Cooling Systems GmbH 369779_1_1019 51 671 ...
Страница 77: ...fr AHT Cooling Systems GmbH 369779_1_1019 77 671 ...
Страница 103: ...it AHT Cooling Systems GmbH 369779_1_1019 103 671 ...
Страница 130: ...AHT Cooling Systems GmbH pt 130 671 369779_1_1019 ...
Страница 156: ...AHT Cooling Systems GmbH es 156 671 369779_1_1019 ...
Страница 183: ...bg AHT Cooling Systems GmbH 369779_1_1019 183 671 ...
Страница 208: ...AHT Cooling Systems GmbH da 208 671 369779_1_1019 ...
Страница 232: ...AHT Cooling Systems GmbH et 232 671 369779_1_1019 ...
Страница 257: ...fi AHT Cooling Systems GmbH 369779_1_1019 257 671 ...
Страница 284: ...AHT Cooling Systems GmbH el 284 671 369779_1_1019 ...
Страница 309: ...hr AHT Cooling Systems GmbH 369779_1_1019 309 671 ...
Страница 334: ...12 Demontāža un likvidācija AHT Cooling Systems GmbH lv 334 671 369779_1_1019 ...
Страница 359: ...lt AHT Cooling Systems GmbH 369779_1_1019 359 671 ...
Страница 385: ...nl AHT Cooling Systems GmbH 369779_1_1019 385 671 ...
Страница 411: ...pl AHT Cooling Systems GmbH 369779_1_1019 411 671 ...
Страница 438: ...AHT Cooling Systems GmbH ro 438 671 369779_1_1019 ...
Страница 463: ...sv AHT Cooling Systems GmbH 369779_1_1019 463 671 ...
Страница 488: ...AHT Cooling Systems GmbH sk 488 671 369779_1_1019 ...
Страница 513: ...sl AHT Cooling Systems GmbH 369779_1_1019 513 671 ...
Страница 538: ...AHT Cooling Systems GmbH cs 538 671 369779_1_1019 ...
Страница 541: ... AHT Cooling Systems GmbH 369779_1_1019 541 671 ...
Страница 565: ...565 671 ...
Страница 590: ...369779_1_1019 ...
Страница 592: ...369779_1_1019 Copyright AHT Cooling Systems GmbH Все права защищены ...
Страница 619: ...ru AHT Cooling Systems GmbH 369779_1_1019 619 671 ...
Страница 622: ...Pregled modela uređaja AHT Cooling Systems GmbH sr 622 671 369779_1_1019 ...
Страница 645: ...sr AHT Cooling Systems GmbH Demontaža i odlaganje 12 369779_1_1019 645 671 ...
Страница 670: ...12 Demontaj ve tasfiye AHT Cooling Systems GmbH tr 670 671 369779_1_1019 ...
Страница 671: ......