Programming And Configuration Items

1.   Displays   and “Keypad Lockout” when in keypad 

lockout mode. 
Displays   and “Temperature Limit” and “Keypad 
Lockout” when limited range is activated and locked. 
Displays only “Temperature Limit” when limited range is 
activated.

2.    Indicates period of day being programmed.

3. 

  RUN SCHEDULE (run program) key.

4. 

  SET TIME key or HOLD temperature key.

5.    Displays “Change Filter”/“Change Pad”/“Change UV 

Lamp” when the system has run for the programmed 

filter/humidity pad/UV lamp time period as a reminder to 

change or clean your filter/humidity pad or to replace UV 

lamp.

6.    COPY key or INSTALLER CONFIG key.

7.    CLEAN DISPLAY key allows 30 seconds to wipe off the 

display or ADVANCE DAY key for programming.

8. 

  Used in programming to set time and in configuration 

menu to change selections.

9. 

  “Hold Until” indicates the time when a temporary hold 

period will end.

10. 

  “Hours” and “Days” displays during steps in installer 

configuration.

11. 

  The words “Hold At” are displayed when the thermostat 

is in the HOLD mode. “Temporary Hold At” is displayed 

when the thermostat is in a temporary HOLD mode.

12. 

  “Humidity” indicates that the “Set At” display is 

Humidity setpoint.

13.   “System On” indicates when heating or cooling stage 

is energized. “+2” indicates when a second stage is 
energized.

14.   “Copy” indicates the copy program feature is being used 

during programming.

15.   A steady “Cool Savings” display indicates the feature is 

enabled in the installer menu. A flashing “Cool Savings” 

display indicates the feature is active.

16.   “Remote” indicates that the indoor remote temperature 

sensor, is being accessed. “Outdoor Remote” indicates 
the outdoor remote temperature sensor is being accessed.

17.   Display time, remote temperature or humidity.

18. 

  “Heat Pump” displays when the system configuration is 

set in HP1/HP2.

19.   “Call for Service” indicates a fault in the heating/cooling 

systems. It does not indicate a fault in the thermostat.

20.   Auto Schedule key for Auto Schedule function or 

Humidity key to display current Humidity and Humidity 

setpoint.

Содержание 910121750

Страница 1: ...And Configuration Items 6 Installer Configuration Menu 7 Operating Your Thermostat 10 Heating 10 Cooling Dehumidifier 11 Choose The Fan Setting Auto or On 11 Choose The System Setting Cool Off Heat Au...

Страница 2: ...izontal Enfinity W CCH CCW MicroTech III Unit Controller Yes Vertical W VFC VFW Vertical Stacked W VHC Console W MHC MHW Horizontal Vertical SmartSource 1 Stage W GSH GSV MicroTech III SmartSource Uni...

Страница 3: ...rews Lev eling is for appearance only and will not affect thermostat operation 5 Connect wires to terminal block on base using appropri ate wiring schematic 6 Push excess wire into wall and plug hole...

Страница 4: ...ower for heating 24V power for heating C 24V common 24V common Y Compressor cool 1st stage Compressor cool 1st stage Y2 No output Compressor cool 2nd stage W1 Compressor heat 1st stage Compressor heat...

Страница 5: ...h the following heat pump systems Heat Pump Type 1 HP1 Single stage compressor system with electric backup Heat Pump Type 2 HP2 2 stage compressor system with electric backup Note After wiring see Ins...

Страница 6: ...iguration menu to change selections 9 Hold Until indicates the time when a temporary hold period will end 10 Hours and Days displays during steps in installer configuration 11 The words Hold At are di...

Страница 7: ...4 On ds OFF Selects Daylight Saving Time calculation 15 On Heat AS OFF Selects Automatic Schedule for comfort temperature programming heat mode Not available if 4 is 0 16 On Cool AS OFF Selects Automa...

Страница 8: ...ostat compressor time delay is activated it will flash the set point for up to five minutes 10 Select Continuous Display Lighting dL In low lighting conditions display backlight improves the display c...

Страница 9: ...ss to advance the menu Three security settings are available in this menu item Use the or keys to select the lockout desired Lockout selections are Keypad Lockout and L Total Lockout Total Lockout loc...

Страница 10: ...32 33 Change UV Lamp This feature allows the thermostat to display the words Change UV Lamp Call for Service of UV bulb after a set time of UV bulb operation This is a reminder to maintain your UV sys...

Страница 11: ...ling may be required on the same day AUTO allows the thermostat to automatically select heating or cooling depending on the indoor temperature and the selected heat and cool temperatures When using AU...

Страница 12: ...h to copy this same program into other days press Copy and repeat steps 3 4 and 5 7 Press Run Schedule to return to normal operation Fill in the blank schedule on page 14 then Enter the Heating Progra...

Страница 13: ...d with the energy saving set tings shown in the table below for all days of the week If this program suits your needs simply set the thermostat clock and press the RUN key The Table 4 shows the factor...

Страница 14: ...24 VAC Common connection to terminal C for the remote sensor to operate The remote sen sor can be enabled or disabled in the Installer Configuration menu item 29 When remote sensor Remote is selected...

Страница 15: ...he thermostat the current temperature displayed will be the weighted average of the local sensor and the remote sensor using the formula local sensor weight local sensor temperature remote sensor weig...

Страница 16: ...he heating is operating correctly No Cool 1 Cooling system requires service or thermostat requires replacement Same as diagnostic for No Heat condition except set the thermostat to COOL and lower the...

Отзывы: