SiUS121736EA
Field Settings
Trial Operation and Field Settings
242
5.3.4 MAIN/SUB Setting when Using 2 Wired Remote Controllers
Outline
The MAIN/SUB setting is necessary when 1 indoor unit is controlled by 2 remote controllers. When
you use 2 remote controllers, set one to MAIN and the other to SUB.
Details
1. The following message is displayed after power-on.
Checking the connection.
Please stand by.
When the above message is displayed, the backlight will not be ON.
[In the case that 1 indoor unit is controlled by 2 remote controllers:]
Make sure to set the sub remote controller when the above message is displayed.
Hold
Mode
button for 4 seconds or longer to set.
When the display is changed from “Main RC” to “Sub RC” the setting is completed.
2. Basic screen is displayed.
<Sub remote controller>
1
1
<Basic screen>
2
<Basic screen>
2
Fan
Fan
<Main remote controller>
Checking the connection.
Please stand by.
Main RC
Checking the connection.
Please stand by.
Main RC
Error Code U5
Checking the connection.
Please stand by.
Main RC
Error Code U5
Checking the connection.
Please stand by.
Main RC
Press and hold 4 seconds
or longer
Mode
button of
sub remote controller side.
Checking the connection.
Please stand by.
Sub RC
Содержание 4MXS-R Series
Страница 7: ...SiUS121736EA Table of Contents vi 3 Operation Limit 267...
Страница 23: ...SiUS121736EA Specifications 10 Part 2 Specifications 1 RA Indoor Unit 11 2 SA Indoor Unit 19 3 Outdoor Unit 22...
Страница 133: ...SiUS121736EA Wired Remote Controller BRC944B2 Remote Controller 120 6 Wired Remote Controller BRC944B2...