6. Silicone Grease on Power Transistor/Diode Bridge
Outline
Apply the specified silicone grease to the heat radiation part of a power transistor/diode bridge
when you replace an outdoor unit PCB. The silicone grease encourages the heat radiation of a
power transistor/diode bridge.
Details
1. Wipe off the old silicone grease on the refrigerant pipe completely.
2. Apply the silicone grease on the heat sink evenly. See the illustrations below for examples of
application.
3. Tighten the screws of cover.
4. Make sure that the heat radiation parts are firmly contacted to refrigerant pipe.
Smoke emission may be caused by bad heat radiation when the silicone grease is not appropriately
applied.
OK: Evenly applied
R7000168
NG: Not evenly applied
R7000158
NG: Foreign matter is stuck.
R7000159
Power transistor
(or diode bridge)
Silicone grease
Silicone grease,
which you do not
need to apply.
Heat sink
PCB
Refrigerant pipe
Cover
Foreign matter
Содержание 4MXL-T Series
Страница 107: ...SiUS121827E SA Indoor Unit Functions Part 4 Functions and Control 101 FFQ Series Emergency operation switch R24077 ...
Страница 182: ...Troubleshooting for RA Indoor Unit SiUS121827E 176 Part 6 Service Diagnosis Reference Check No 11 Refer to P 235 ...
Страница 190: ...Troubleshooting for SA Indoor Unit SiUS121827E 184 Part 6 Service Diagnosis Reference Check No 02 Refer to P 233 ...
Страница 249: ...SiUS121827E Check Part 6 Service Diagnosis 243 R6000583 1 2 3 4 Multimeter Front side Rear side ...
Страница 288: ...Piping Diagrams SiUS121827E 282 Part 8 Appendix 1 2 Outdoor Unit 5MXS48TVJU 4MXL36TVJU 3D117817 3D118311 ...
Страница 298: ...Operation Limit SiUS121827E 292 Part 8 Appendix 4 Operation Limit 5MXS48TVJU 4MXL36TVJU 3D048149D 3D101428 ...