9
|
Electrical installation
Installer reference guide
52
4MWXM-A
R32 Split series
4P678385-1A – 2022.02
Component
Residual current device
MUST comply with applicable
legislation
Electrical equipment must comply with EN/IEC 61000-3-12, the European/
International Technical Standard setting the limits for harmonic currents produced
by equipment connected to public low-voltage systems with input current >16 A
and ≤75 A per phase.
9.2 To connect the electrical wiring to the outdoor unit
1
Remove the switch box cover (1 screw).
1
2
1×
2
Strip insulation (20 mm) from the wires.
a
b
a
Strip wire end to this point
b
An excessive strip length may cause electrical shock or leakage
3
Connect the wires between the indoor and outdoor units so that the terminal
numbers match. Make sure to match the symbols for piping and wiring.
4
Make sure to connect correct wiring to correct room.
d
(B)
d
(C)
d
(TO TANK)
A
d
(A)
C
TO TANK
B
a
b
c
A
Terminal for room A
B
Terminal for room B
C
Terminal for room C
TO TANK
Terminal for DHW tank
a
Circuit breaker
b
Residual current device
c
Power supply wire
d
Interconnection wire for room (A, B, C, TO TANK)
5
Tighten the terminal screws securely using a Phillips screwdriver.
6
Check that the wires do NOT disconnect by pulling them lightly.
7
Firmly secure the wire retainer to avoid external stress on wire terminations.
Содержание 4MWXM-A
Страница 1: ...Installer reference guide R32 Split series 4MWXM52A2V1B ...
Страница 32: ...6 Unit installation Installer reference guide 32 4MWXM A R32 Split series 4P678385 1A 2022 02 ...
Страница 77: ......
Страница 78: ......
Страница 79: ......
Страница 80: ...4P678385 1A 2022 02 Copyright 2021 Daikin Verantwortung für Energie und Umwelt ...