Removal of Electrical Box
Si00-771
10
Removal Procedure
2. Removal of Electrical Box
Procedure
Warning
Be sure to wait for 10 minutes or more after turning off all power
supplies before disassembling work.
Step
Procedure
Points
1
Disconnect the 2
connectors for the
reactor.
Preparation
Remove the outer panels
and disconnect the
connector for the fan motor
according to the “Removal of
Outer Panels / Fan Motor”.
2
Cut the clamp.
Some models do not have
the clamp.
3
Disconnect the
connector for the
compressor [S30].
When reassembling, coil the
excessive lead wire and
hang the loop on the hook.
(R16469)
(R16470)
(R7216)
[S30]