Daiichi Electronics STT2-92A Скачать руководство пользователя страница 7

Q-222-038 

 

 

5. Connection 

 

Refer to the terminal name on the front name plate of the main unit, and connect according to the wiring  
diagram below or the wiring diagram name plate on the lower side of the main unit. 
Use the included M4 screws to connect the auxiliary power supply, input voltage, input current, output,  
and ground terminals. 

〔Applicable solderless terminal〕  

Solderless terminal for M4 screw 
Outer diameter of terminal, 8.5mm or less 
Tightening torque:1.0 to 1.3 N・m 

 
 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 

■ Connection diagram 

( )

AUX.SUPPLY

( )

OUTPUT

A

( ) ( )

B

1

U

LOAD

2

3

V

U

E

LOAD

4

V

1 2

BUS

2

START

1

 

 

・Grounding is class D grounding (grounding resistance 100Ω or less). 
・If there is a power line that causes noise or a sharp voltage fluctuation, separate the output  

wiring as much as possible.  In addition, use twisted cable or shielded twisted cable. 

・This product will not be damaged even if the output terminal is left open in the current output 

specifications. 

・After completing the wiring work, attach the terminal cover. 

 

Output terminal 
A(+), B(-) 

Input voltage terminal 
1, 2, 3, 4 
 
 
 
 
 
 
 

Ground terminal 

Auxiliary supply terminal 

S1(  ), S2(  ) 

+ 

~ 

- 

~ 

Содержание STT2-92A

Страница 1: ...Q 222 038 INSTRUCTION MANUAL V V PHASE ANGLE TRANSDUCER STT2 92A MODEL B...

Страница 2: ...ase do not install in the place where sunlight hits directly Discoloration and degradation of a name plate and deformation of the case by the surface temperature rise may occur If the average daily te...

Страница 3: ...our company Failure caused by violating various conditions regarding use storage etc specified by the supplier When the faults or defects are caused by a reason not belongs to purchased or delivered p...

Страница 4: ...thod 4 5 Connection 6 6 Handling explanation 7 7 Specification 7 1 Rating 8 7 2 Performance 8 7 3 Electrical strength Mechanical strength 9 7 4 Noise immunity 9 7 5 EMC 10 7 6 Structure and environmen...

Страница 5: ...certificate 1 Packed in an envelope Terminal screw in a bag M4 screw 4 piece set 1 M4 screw 5 piece set 1 4 Mounting method Please install indoors in a place with low mechanical vibration dust and co...

Страница 6: ...e this product from the IEC DIN rail Please insert a flathead screwdriver in the hole where a slider is square Next a slider is lowered in the direction of an arrow This product can be removed from th...

Страница 7: ...ss Tightening torque 1 0 to 1 3 N m Connection diagram AUX SUPPLY OUTPUT A B 1 U LOAD 2 3 V U E LOAD 4 V 1 2 BUS 2 START 1 Grounding is class D grounding grounding resistance 100 or less If there is a...

Страница 8: ...adjustment range is BIAS 5 of the output span MAX 5 of the output span Use only when adjustment is required for matching with connected devices 5 The output value when only the auxiliary power supply...

Страница 9: ...r to the specification code for other ratings 7 2 Performance Item Specification Class index 1 0 Response time 1 second or less Ripple 1 p p or less Fluctuation value of influence due to ambient tempe...

Страница 10: ...tion of rated voltage DC100 110V DC57V continuous DC48V Short time over input Input 2 times 10 seconds of rated voltage once 2 times 1 second of rated voltage 10 times 10 second intervals Aux supply 1...

Страница 11: ...61000 4 6 Power frequency magnetic field immunity test Frequency 50 60Hz Field strength 30A m Performance standard A During testing Within 20 error After test Within inherent error EN61000 6 2 EN61000...

Страница 12: ...d 7 7 Technical standards Item Specification Transducer JIS C 1111 2019 IEC 60688 2012 CE marking EMC Directive 2014 30 EU EN 61000 6 2 EN 61000 4 2 3 4 5 6 8 11 EN 61000 6 4 EN 55011 classA Group1 Lo...

Страница 13: ...or 45 or 90 and adjust to the rated output value with MAX adjustment VR The screwdriver for adjustment Tip width of 1 8 to 2 3mm Phillips head screwdriver or flat blade screwdriver 10 Type compositio...

Страница 14: ...Hitotsuya 1 chome Adachi ku Tokyo 121 8639 JAPAN TEL 81 3 3885 2411 FAX 81 3 3858 3966 Kyoto Office 1 19 Ichinobe Nishikawahara Jyoyou shi Kyoto 610 0114 JAPAN TEL 81 774 55 1391 FAX 81 774 54 1353 R...

Отзывы: