M
EMORY
F
UNCTION
OF
W
ELDING
C
ONDITIONS
W
ELDING
C
ONDITION
C
HAPTER
6
6-10
NOTE
• When the analog remote control is connected to the machine, even if the stored welding
condition is read, the set values of the analog remote control apply to the welding current
and welding voltage of welding condition.
TIPS
• Use of the internal function (F44) enables to read out the registered welding condition by the
analog remote control (optional). (
-
• Use of the internal function (F11) enables to finely adjust the current/voltage values read out
from the memory by the analog remote control (optional). (
-
6.5.1 Memory registration of welding conditions
This section explains how to register the current welding condition set on the operation panel to the
memory.
1.
Press the SAVE key.
2.
Turn the parameter adjustment knob, and select the JOB No.
• The welding conditions (electronic data) stored by this function are susceptible to
occurrence of static electricity, impact, repair, etc., and there is a possibility that the
stored contents may be changed or lost. BE SURE TO MAKE A COPY FOR IMPORTANT
DATA.
• Please note that OTC will not be liable for any alteration or loss of electronic
information.
⇒
The system transits to the storage function mode and
the LED of the SAVE key lights up.
⇒
The JOB No. (registration No.) is displayed on the
right digital meter in a flashing mode, and the LED
of JOB No. lights up.
⇒
On the left digital meter, the setting value of the
welding current registered to the JOB No. if any is
displayed (if there is no registration, "- - -" is
displayed), and the "A" LED lights up.
⇒
When there is no registration data on the selected
JOB No., "- - -" is displayed on the left digital meter.
⇒
When there is any registration data on the selected
JOB No., the setting value of the welding current is
displayed on the left digital meter. At this time, the
LEDs for the keys of crater or wire material also light
up.
A
V
s
㸣
m/min.
sec.
JOB No.
SAVE
DC NO-LOAD VOLTAGE
Hz
A
V
s
㸣
m/min.
sec.
JOB No.
DC NO-LOAD VOLTAGE
Hz
Содержание OTC Welbee Inverter W400
Страница 2: ......
Страница 8: ...vi MEMO...
Страница 56: ...WIRING OF VOLTAGE DETECTION CABLE AT BASE METAL SIDE CONNECTION CHAPTER 4 4 22...
Страница 116: ...OPERATION OF ANALOG REMOTE CONTROL OPTIONAL WELDING CONDITION CHAPTER 6 6 50...
Страница 134: ...CHECKING SOFTWARE VERSION ADMINISTRATOR FUNCTIONS CHAPTER 7 7 18...
Страница 146: ...TROUBLESHOOTING TROUBLESHOOTING CHAPTER 9 9 6...
Страница 150: ...REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 10 4 10 2 1 Schematic diagram...
Страница 151: ...10 5 Chapter 10 Reference Materials REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10...
Страница 158: ...MATERIALS FOR SETTING WELDING CONDITIONS REFERENCE MATERIALS CHAPTER 10 10 12...