L
IST
OF
W
ELDING
C
ONDITIONS
W
ELDING
C
ONDITION
C
HAPTER
6
6-2
6.1.3 Internal function
Details of internal function (
The functions with circle mark (O) on the Memory row can be stored with the welding conditions.
No.
Function Name
Setting range
Initial value
Explanation
Memory
F1
Standard/Extended
cable mode
OFF/ON
OFF
Sets the waveform control mode for voltage
detection when using the welding power source in
the STANDARD mode.
OFF: STANDARD mode (standard mode)
ON: Extended cable mode (extended mode of
power cable)
-
F2
Switch of AC start
0.00 to 2.00
0.30
Sets the switching time to start AC welding in the
AC welding.
-
F3
Crater (no pulse) setting
OFF/ON
OFF
Sets the presence (ON/OFF) of the pulse in crater
treatment.
OFF: Crater (with pulse)
ON: Crater (no pulse)
-
F4
Auto/Semi-auto mode
0/1/2/3/4
0
Switches the I/O settings of the welding power
source:
0: Semi-automatic machine
1: Automatic machine 1
2: Automatic machine 2
3: Almega (OTC’s robots) specification
4: Almega (OTC’s robots) specification (for high
speed communication)
-
F5
Maximum external
command voltage
10.0/14.0/15.0
15.0 (V)
Sets the maximum value of voltage supplied when
current/voltage command is externally input.
-
F6
Up slope time
0.0 to 10.0
0.0 (s)
Sets the slope time from the initial condition to
the welding condition.
○
F7
Down slope time
0.0 to 10.0
0.0 (s)
Sets the slope time from the welding condition to
the crater condition.
○
F8
Welding result display time
0 to 60
20 (s)
Sets the display time for the current/voltage after
completion of welding.
-
F9
Analog remote control scale
200/350
350 (A)
Configures the settings of scale plate of the
analog remote control.
-
F10
Motor over current detection
level
20 to 150
70 (%)
Sets the over current warning level for the rated
current of the wire feed motor.
-
F11
Fine adjustment of welding
conditions memory
OFF/1 to 30
OFF
Allows fine tuning the current and voltage of
welding conditions stored on the memory using
the analog remote control.
OFF: No fine adjustment
1 to 30 (%): Fine adjustment is performed
(Maximum adjustment range at this time can be
set in percentage)
-
F12
Operation time of water-
cooled pump
20 to 60/ON
20 (min)
Sets the operation time of water-cooled pump
after welding ends.
Set the time in the range of 20 to 60 minutes or
set to ON (always ON ).
-
F13
No function
OFF (fixed)
OFF
No functions are provided.
-
F14
Start control time
adjustment
-50 to 50
0 (%)
Adjusts the control time of current at the time of
start.
-
F15
Start control current
adjustment
-100 to 100
0 (A)
Adjusts the control of current at the time of start.
-
F16
Slow-down speed
adjustment
-1.0 to 1.0
0.0 (m/
min)
Adjusts slowdown speed.
○
F17
Anti-stick time adjustment
-50 to 50
0 (10ms)
Allows fine tuning meltage of the wire at the end
of welding based on the anti-stick process time.
○
Содержание OTC Welbee Inverter W400
Страница 2: ......
Страница 8: ...vi MEMO...
Страница 56: ...WIRING OF VOLTAGE DETECTION CABLE AT BASE METAL SIDE CONNECTION CHAPTER 4 4 22...
Страница 116: ...OPERATION OF ANALOG REMOTE CONTROL OPTIONAL WELDING CONDITION CHAPTER 6 6 50...
Страница 134: ...CHECKING SOFTWARE VERSION ADMINISTRATOR FUNCTIONS CHAPTER 7 7 18...
Страница 146: ...TROUBLESHOOTING TROUBLESHOOTING CHAPTER 9 9 6...
Страница 150: ...REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 10 4 10 2 1 Schematic diagram...
Страница 151: ...10 5 Chapter 10 Reference Materials REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10...
Страница 158: ...MATERIALS FOR SETTING WELDING CONDITIONS REFERENCE MATERIALS CHAPTER 10 10 12...