7.5 Initializing Welding JOB and Internal Functions
This section explains how to initialize the welding JOB and internal functions.
If initialized, the welding JOB currently used and internal function values will return to the default (initial) setting.
However, this does not affect the welding JOB registered in memory.
The initialization procedure differs depending on whether the touch panel is installed on the wire feeder or on the welding
power source.
NOTE
•
F39 to 42 will not be initialized.
■
When the touch panel is installed on the wire feeder
1.
Turn OFF the power switch.
2.
Turn OFF the breaker.
3.
Remove the cover on the upper front panel of the welding power source.
4.
Change the circuit board switch SW101 setting from 0 to 4.
5.
Install the cover on the upper front panel of the welding power source.
6.
Turn ON the breaker.
7.
Turn ON the power switch.
8.
After more than 10 seconds have passed, turn OFF the power switch.
9.
Repeat steps 1 through 3.
•
When touching the internal parts of the welding power source, always perform the work
after turning off the breaker. Otherwise, electric shock may occur.
㻿㼃㻝㻜㻝
Содержание OTC ARXIS pulse P403L
Страница 1: ...July 2023 Manual No P30433 1 DAIHEN Corporation ARXIS pulse P403L P503L OWNER S MANUAL...
Страница 174: ...REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 172 10 2 1 Schematic diagram ARXIS WB P403L...
Страница 175: ...REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 173 Chapter 10 Reference Materials...
Страница 176: ...REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 174 ARXIS WB P503L...
Страница 177: ...REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 175 Chapter 10 Reference Materials...