background image

10

 

  MAINTENANCE 

This section explains the necessary maintenance work to ensure the proper functioning of the 
Cooling unit. 

  WARNING 

 

ELECTRIC SHOCK can kill. 

 

Be sure to disconnect the line disconnect switch on the connected welding power source 
before maintaining this equipment. Make sure that there is no charged voltage before 
starting the work. 

 

Read the precautions for power supply and electric shock and follow them during the 
whole process of installation.

 

 

  CAUTION 

 

HOT PARTS may cause burns. 

 

Some components can be extremely hot immediately after welding is performed. 
Wait until the parts cool down, when touching. Failure to observe the demand may 
result in burn.

 

To maintain the proper functioning of the equipment, ensure to follow the instructions below: 

 

Make sure no strange vibration, buzzing noise, and burning smell are generated from 
the cooling unit.  

 

No excessive heat is generated from the cable connections. 

 

Make sure all joints are tight and that there are no leaks. 

 

The cooling fan is running normally. 

 

Periodically check the level of the coolant. 

 

Add coolant whenever it drops below the MIN mark. 

 

Periodically  clean  the  fans,  heat  exchanger  and  the  inside  with  compressed  air  to 
eliminate the dust that reduces the cooling capacity. 

 
 
 
 

Содержание OTC 6H/IF

Страница 1: ...OWNER S MANUAL COOLING UNIT MODEL 6H IF Ensure to read this instruction manual thoroughly for safe and proper use of the product MANUAL No 632214 1 2023 11 EN...

Страница 2: ...R HANDLING OF PLASTIC PARTS 5 1 6 PRECAUTION FOR COOLANTS 5 PRODUCT SPECIFICATION 6 2 1 TECHNICAL SPECIFICATIONS 6 2 2 EXTERNAL DIMENSIONS 6 2 3 RATED DUTY CYCLE 7 INSTALLATION 7 3 1 PRECAUTIONS BEFOR...

Страница 3: ...gulations and any regional regulations Only authorized personnel or person with full understanding and experience of the equipment must perform installation maintenance and repair of the equipment Use...

Страница 4: ...ed welding power source before installing maintaining or repairing this equipment Make sure that there is no charged voltage before starting the work Properly install this equipment according to its O...

Страница 5: ...icals cutting oil and composition oil adhere or atmosphere containing the above Doing so may cause crack breaking and deterioration in the plastic part 1 6 PRECAUTION FOR COOLANTS To prevent malfuncti...

Страница 6: ...current Max 0 95A 50Hz 1 1A 60Hz Cooling power 1l min 1 2 kW P MAX 0 45 Mpa 50Hz 0 55 Mpa 60Hz Type of connection water Quick connectors NW5 Number of connections water 1 pair rear Tank volume Require...

Страница 7: ...n the electrical wiring and the mounting of the Cooling unit 3 1 PRECAUTIONS BEFORE AND THE ENVIRONMENT OF THE INSTALLATION WARNING ELECTRIC SHOCK can kill Be sure to disconnect the line disconnect sw...

Страница 8: ...cm 3 Connect the flow sensor connector 6 pole to the right connector in the welding source 4 Connect the power connector 9 pole to the left connector in the welding source 5 Push the cooler all the wa...

Страница 9: ...istrict 2 Using the Pipetting Bulb 606499 squeeze the bulb fully and hold in this condition 3 While the pipette bulb is squeezed connect the connector on the end of the hose with the blue connector on...

Страница 10: ...tremely hot immediately after welding is performed Wait until the parts cool down when touching Failure to observe the demand may result in burn To maintain the proper functioning of the equipment ens...

Страница 11: ...EXCHANGER 258477 1 3 631756 CONNECTOR RED NW 5 G 1 4 003204 R 1 4 631757 CONNECTOR BLUE NW 5 G 1 4 003204 B 1 5 631758 FITTING KQ2E10 G02A KQ2E10 G02A 2 6 631760 FITTING KQ2H10 00A KQ2H10 00A 2 7 6318...

Страница 12: ...12 5 3 8 1 12 10 9 4 11 6 2 3 16 6 13 7 15 6 17 6 14 6...

Страница 13: ...13 WIRING DIAGRAM PM1 Pump motor FM1 2 Fan S1 Flow sensor CN1 2 Connector internal CON1 2 Connector to power source COOLANT CIRCUIT DIAGRAM 5 cm 25 cm 42 cm 33 cm 42 cm...

Страница 14: ...ORIENTO Plaza 388 North Fuquan Road Changning District Shanghai China 200335 Phone 86 21 5882 8633 Fax 86 21 5882 8846 OTC Taiwan Co Ltd 2F No 153 Huanbei Rd Chung Li City Taoyuan Hsien Taiwan Phone...

Отзывы: