Modular Door Station
Quick Start Guide
V1.0.0
Страница 1: ...Modular Door Station Quick Start Guide V1 0 0...
Страница 2: ...tial hazard which if not avoided will result in death or serious injury WARNING Indicates a medium or low potential hazard which if not avoided could result in slight or moderate injury CAUTION Indica...
Страница 3: ...customer service for the latest program and supplementary documentation There still might be deviation in technical data functions and operations description or errors in print If there is any doubt o...
Страница 4: ...vice or put on the device anything filled with liquids Install the device at well ventilated places and do not block its vent Use the device only within rated input and output range Do not dismantle t...
Страница 5: ...int Module 7 Display Module 7 Blank Module 8 Cascade Connection 8 3 Configuration and Commissioning 9 Procedure 9 Configuring VTO 9 3 2 1 Initialization 9 3 2 2 Configuring VTO Number 10 3 2 3 Configu...
Страница 6: ...ed Features Video call Make video calls to indoor monitors VTHs Group call Call multiple VTHs simultaneously Video monitoring Up to 6 VTHs can view the monitoring image of this VTO at the same time Em...
Страница 7: ...2 2 Structure Camera Module Front panel Table 2 1 Front panel description No Name 1 Microphone 2 Camera 3 Speaker Rear panel...
Страница 8: ...rol lock solenoid lock and exit button 3 Ethernet port Connect to network cables 4 Cascade connection port Connect to other modules Ports description Table 2 3 Port description No Description No Descr...
Страница 9: ...ck indicator Rear panel of indicator module Table 2 5 Indicator module description 2 No Name Description 1 Cascade input Connect to other modules 2 Cascade output Audio Module The rear panel of audio...
Страница 10: ...take the five button module as an example Front panel of the five button module Table 2 7 Front panel description No Name Description 1 User directory Put name cards here 2 Call buttons Call other VTH...
Страница 11: ...keyboard module is the same as the button module Keyboard module Table 2 9 Keyboard module description No Name Description 1 Selection 2 Numbers Enter password or VTH numbers 3 Call Call VTHs 4 Call...
Страница 12: ...anels of fingerprint module and button module have different port positions but port functions are the same Fingerprint module Display Module Displays user information Rear panels of display module an...
Страница 13: ...For a better appearance use the blank module if there is an extra space while putting up modules together Blank module Cascade Connection Cascade connection is needed for all the modules to work toget...
Страница 14: ...hone number for each device Configure the VTO See 3 2 Configuring VTO Configure the VTH See the VTH user s manual Check if all settings are correct See 3 3 Commissioning Configuring VTO Connect the VT...
Страница 15: ...n interface 3 2 2 Configuring VTO Number Numbers can be used to distinguish each VTO and we recommend setting it according to unit or building number You can change the number of a VTO when it is not...
Страница 16: ...3 2 4 Configuring SIP Servers When connected to the same SIP server all VTOs and VTHs can call each other You can use a VTO or other servers as the SIP server If the current VTO is the SIP server Bui...
Страница 17: ...VTO cannot call the VTS Port 5060 by default when VTO work as SIP server 5080 by default when the platform works as SIP server Username Password Keep it default SIP Domain Must be VDP when VTO works...
Страница 18: ...connected to the same SIP server can make video call between each other This section is applicable when a VTO device works as SIP server and if you are using other servers as SIP server see the corre...
Страница 19: ...er on VTH devices to connect them to the network This section is applicable when the VTO works as the SIP server and if you use other servers as SIP server see the corresponding manual of the servers...
Страница 20: ...ould end with 0 and the room numbers for sub VTHs with 1 2 You can have up to 10 sub VTHs for one main VTH Registeration Type Select public Registeration Password Keep it default Click Save Click or t...
Страница 21: ...tting VTH Management You can add a single room number or add them in batches Add a single room number Add room numbers 1 Click Add Add a single room number 2 Configure the information on the left See...
Страница 22: ...2 Click Add and then click Refresh to view the latest status Click or to modify or delete a room number Click Clear to delete all room numbers 3 2 7 Configuring the Module Camera module is added by d...
Страница 23: ...o bottom and from left to right Click Confirm and then restart the browser to apply the changes 3 2 7 2 Configuring Modules You need to configure room numbers for the button module Select Local Settin...
Страница 24: ...Confirm and then restart the browser to apply the changes Commissioning 3 3 1 VTO Calling VTH Dial a room number on the VTO Press Tap on the VTH to answer the call Call screen 3 3 2 VTH Monitoring VT...
Страница 25: ...20 Door Select the VTO that you want to monitor Monitoring video...
Страница 26: ...ggest that you download and use the latest version of client software Nice to have recommendations to improve your device network security 1 Physical Protection We suggest that you perform physical pr...
Страница 27: ...inder encrypted transmission will cause some loss in transmission efficiency 11 Secure Auditing Check online users we suggest that you check online users regularly to see if the device is logged in wi...