Appendix 1 Lightning and Surge Protection

 

The Camera adopts TVS lightning protection technology. It can effectively prevent damage from 
various pulse signals below 6000 V, such as a sudden lightning and surge. However, you still need to 
take necessary precaution measures in accordance with your local electrical safety code when 
installing the Camera in outdoor environment. 

  The distance between the signal transmission cable and high-voltage device (or high-voltage 

cable) shall be at least 50 m. 

  Outdoor cable layout shall go under the penthouse if possible. 

  For vast land, use sealing steel tube under the land to implement cable layout and make sure 

that both ends of the tube are equipotentially grounded. Open floor cable layout is forbidden. 

  For vast land, install a 10 KA lightning rod near the Camera’s power input port and Ethernet port. 

For Camera with AC to DC power adapter, install a 10 KA lightning rod near the output port of 
the adapter. 

  For Camera installed on iron tower, if there is a high-performance grounding bar on the tower, 

connect the Camera grounding wire to the bar. If there is no grounding bar, use multiple copper 
cable whose cross-sectional area are not less than 16 mm² to connect the Camera grounding wire 
into the ground. 

  Make sure that the Camera is over 3 m away from the top point of tower lightning rod and within 

protection area against direct lightning. 

  In area of strong thunderstorm or near high sensitive voltage (such as near high-voltage 

transformer substation), install additional high-power thunder protection device or lightning rod. 

  The thunder protection and earth grounding of the outdoor devices and cables shall be 

considered based on the whole thunder protection of the building and conform to your local or 
industry standards. 

  The system shall adopt equal-potential wiring. The grounding devices shall meet anti-jamming 

requirements and at the same time conforms to your local electrical safety code. 

  The grounding devices shall not be connected to N (neutral) line of high voltage power grid or 

mixed with other wires. When you connect the system to the ground alone, the grounding 
resistance shall not be more than 4Ω and the cross-sectional area of grounding cable shall be no 
less than 25 mm².   

Содержание TPC-KF2241-T

Страница 1: ...Thermal Network Hybrid Thermography Cube Camera Quick Start Guide V1 0 0...

Страница 2: ...cy protection laws and regulations to protect the legitimate rights and interests of other people by implementing measures which include but are not limited Providing clear and visible identification...

Страница 3: ...ftware if the manual in PDF format cannot be opened All trademarks registered trademarks and company names in the manual are properties of their respective owners Please visit our website contact the...

Страница 4: ...mergency power off when necessary Prevent the line cord from being trampled on or squeezed especially the plug power socket and the junction from the Camera Application Environment Requirements Please...

Страница 5: ...then softly wipe the dirt away Clean the Camera body with a piece of soft dry cloth For any dirt that is hard to remove pick up a piece of clean and soft cloth dip it into a little neutral detergent...

Страница 6: ...5 3 3 Live Video 5 4 Installation 7 4 1 Preparations 7 4 1 1 Checking Installation Space and Intensity 7 4 1 2 Cable Preparation 7 4 2 Installing Camera 8 4 2 1 Restoring to Default Settings 8 4 2 2 I...

Страница 7: ...he installation process do not come with the delivery Please buy them if they are needed Keep accessories safe for future use Figure 1 1 Checklist Table 1 1 Checklist No Name Quantity No Name Quantity...

Страница 8: ...2 2 Design 2 1 Dimensions Figure 2 1 Component dimensions mm inch 2 2 Cables The following figure of the cable is for reference only and might differ from the actual product...

Страница 9: ...nputs 12 VDC Supply power to the device according to the label to avoid damages to the Camera 3 RS 485 RS 485 port Connects to external RS 485 devices 4 ALARM_OUT Alarm output port Alarm devices such...

Страница 10: ...t a time log in to the web interface Initialize the device for first time use after performing a factory reset To keep the data on the Camera secure keep the admin password safe after initialization a...

Страница 11: ...re 3 2 TCP IP Step 3 Configure IP related parameters Step 4 Click Save 3 3 Live Video The web interface might differ depending on the device Figures in this guide are for reference only Step 1 Log in...

Страница 12: ...install a plug in for first time system login Please download and install the plug in The web interface will refresh automatically after the plug in is installed and then the live video will be displa...

Страница 13: ...eparation Power Cord To extend the power cord you have received evaluate the distance you want to extend to and then select the appropriate cord diameter Table 4 1 Power cord description Distance ft m...

Страница 14: ...on for more than 10 s to reset the Camera to factory settings Figure 4 1 Component Network indicator It flashes orange when the network is connected Power indicator Before the Camera starts it is red...

Страница 15: ...Paste the positioning map Choose a suitable mounting surface and then paste the positioning map to the surface Drill the holes according to the label signs Figure 4 3 Paste the positioning map Step 2...

Страница 16: ...10 Figure 4 4 Secure the Camera Step 3 Remove the label After attaching the Camera to the mounting surface remove the label from the lens Figure 4 5 Remove the label...

Страница 17: ...Camera collects logic 0 Figure 5 1 Alarm input Step 2 Connect the alarm output device to the alarm output port of I O cable Alarm output Port ALARM_OUT and GND form a switch to provide alarm output T...

Страница 18: ...12 Figure 5 3 Alarm setting...

Страница 19: ...ounding bar on the tower connect the Camera grounding wire to the bar If there is no grounding bar use multiple copper cable whose cross sectional area are not less than 16 mm to connect the Camera gr...

Страница 20: ...14 Figure 1 1 Lightening protection...

Страница 21: ...cabinet and implement well done access control permission and key management to prevent unauthorized personnel from carrying out physical contacts such as damaging hardware unauthorized connection of...

Страница 22: ...we suggest that you check online users regularly to see if the device is logged in without authorization Check device log By viewing the logs you can know the IP addresses that were used to log in to...

Отзывы: