Figure 6-72 Relay Activation
Step 2.
Select Enable.
Step 3.
Set alarm parameters.
Please refer to the following sheet for log parameter information.
Parameter
Function
Relay-in
Support 2 channels of alarm input.
Period
Set alarm arm and disarm period. Click on setup button to open period menu.
Anti-dither
During anti-dither period, only one alarm will be recorded. Unit is second with range
0s
~
100 s.
Sensor type
May set NO or NC.
Chart 6-28
Step 4.
Select Relay-out accordingly, and set port no. and alarm delay time.
Step 5.
Click OK.
6.5.4.1.2 Relay-out