1.1

Working with body camera, the Station can acquire the data of body cameras and charge them. The 
Station can auto recognize and connect the connected body camera through the USB port. Working 
with Portable Mobile Center Platform, the Station can authorize the body camera, auto acquire the 
electronic evidence (video, audio, and snapshot). The Station contains control module and data 
collection module. One control module can support 4 data collection modules at most. It is featured 
with: 

 

Recharge and collect data from maximum 32 body cameras at the same time 

 

Automatically or manually upgrade body cameras. 

 

Automatically create archive and then save the collected electronic data. 

 

Automatically upload the evidence to FTP or Portable Mobile Center Platform. 

 

Automatically synchronize time. 

 

When there are more than 1 data collection modules, the Station will collect data from the body 
camera in the fixed docks of each data collection module in priority. 

 

You can search, edit, transcode, play back, view, delete and manage all the data in the Station. 

Содержание EEC300D8-N1

Страница 1: ...Data Collection Station Quick Start Guide V1 0 1...

Страница 2: ...hazard which if not avoided could result in slight or moderate injury CAUTION Indicates a potential risk which if not avoided could result in property damage data loss lower performance or unpredictab...

Страница 3: ...entilated place and do not block the ventilation of the Scanner Operate the Station within the rated range of power input and output Do not disassemble the Station Transport use and store the Station...

Страница 4: ...1 3 Power on 6 1 4 Device Connection 6 1 5 1 5 1 Connecting Control Module and Data Collection Module 6 1 5 2 Connecting Body Camera and Data Collection Module 6 2 HDD Installation 10 3 Configuration...

Страница 5: ...rol module can support 4 data collection modules at most It is featured with Recharge and collect data from maximum 32 body cameras at the same time Automatically or manually upgrade body cameras Auto...

Страница 6: ...2 Product Appearance 1 2 1 2 1 Control Module Front panel and rear panel Figure 1 1...

Страница 7: ...each user 4 Adjusting board Remove the control module when connecting control module and data collection modules 5 Rear cover 6 White light Provides extra light when recognizing faces Provides extra l...

Страница 8: ...ntrol module and data collection modules 10 Heat dissipation hole 11 Ports Include power input port USB ports Ethernet ports and RS 232 port For details see Table 1 2 1 2 2 Appearance of Data Collecti...

Страница 9: ...le 1 2 Port description No Name Description 1 Power input Inputs 100 V 240 V AC power for the Station After shutting down the Station the fan will work for a period to cool the Station 2 USB ports Con...

Страница 10: ...tion module according to the instruction on the positioning map Step 3 1 5 2 Connecting Body Camera and Data Collection Module After starting the Station connect body cameras to the Station and then y...

Страница 11: ...7 Take out data cable MPT220 slot Figure 1 5 Take out data cable MPT210 slot Figure 1 6 Connect the data cable to the body camera until the Station pops up connection successful Step 2 dialog box...

Страница 12: ...put the body camera into the dock and then you can collect data and Step 3 recharge the body camera For MPT220 body camera insert the device into the slot For MPT210 body camera insert the clip into...

Страница 13: ...9 Data collection MPT220 slot Figure 1 9 Data collection MPT210 slot Figure 1 10...

Страница 14: ...ach HDD we recommend you to install at least 2 HDDs with the same capacity for data collection and recharging Loosen the screws on the rear cover and then remove the rear cover Step 1 Remove rear cove...

Страница 15: ...s Step 4 Fix HDD Figure 2 4 Install HDDs Push the fixed HDDs in the HDD box Step 5 Install HDD Figure 2 5 Push HDDs in the direction as the HDD port and main board port show Fix the HDD box in the cha...

Страница 16: ...12 Connect the cable between main board and HDD plate Step 7 Fix the cover Step 8 Fix the cover Figure 2 7...

Страница 17: ...13 3 Configuration and Operation Main interface Figure 3 1 Table 3 1 Main interface description No Description 1 Unlock the dock by one tap 2 Alarm Tap it and the alarm tune is disabled...

Страница 18: ...each data collection module 9 View update methods of the Station and body cameras Click Bind Enforce on the Device Info interface enter the enforcer name and enforcer No click Search and then select...

Страница 19: ...15 User management Figure 3 2 Click Add to add users Step 2 You can add faces and fingerprints and configure user permissions All permissions are enabled by default Add users Figure 3 3...

Страница 20: ...users Enter enforcer department enforcer No enforcer name password and confirm password and add face and fingerprint as needed Adding enforcer Figure 3 4 3 2 3 Resetting Password Select Setting Accou...

Страница 21: ...17 Resetting password Figure 3 5...

Страница 22: ...ates function to obtain timely information of firmware updates released by the manufacturer We suggest that you download and use the latest version of client software Nice to have recommendations to i...

Страница 23: ...ve we recommend that you use encrypted transmission function to reduce the risk of audio and video data being stolen during transmission Reminder encrypted transmission will cause some loss in transmi...

Страница 24: ...20 Enable IP MAC address filtering function to limit the range of hosts allowed to access the device...