![Dahua ARD1611-W Скачать руководство пользователя страница 11](http://html1.mh-extra.com/html/dahua/ard1611-w/ard1611-w_manual_500628011.webp)
7
7.
Use of Product
LED Setup
You can set LED jumper stitch to control LED indicator. Indicator have two mode: ON and
OFF.
You can set two shifts at position of jumper stitch: 1&2(P1) and 2&3(P2), select P1 as
LED-OFF and P2 as LED-ON. Default mode is LED-ON.
Note:
Operation of detector will not be affected.
Pulse Count
You may set P.COUNT (pulse count) pulse according to product usage environment and
detection distance.
You can set two shifts at position of jumper stitch: 1&2(P1) and 2&3(P2), select P1 to be
first level pulse, and P2 to be second level pulse. P2 is selected by default. Please note
that P2 detectuon has higher sensitivity than P1 detection.
Installation Test
You can test the working status of detector, see:
Within the detectable area of detector, test by normal walk speed of 1m/s, and the red
indicator keeps ON for 2 seconds. This represents that IR has been triggered, d etector is
in alarm status now and outputs alarm signal, so red indicator turns ON.