171
Parameter
Function
Record Delay
System can delay the record for specified time after alarm
ended. The value ranges from 10s to 300s.
Alarm out
Enable alarm activation function. You need to select alarm
output port so that system can activate corresponding
alarm device when an alarm occurs.
Latch
System can delay the alarm output for specified time after
an alarm ended. The value ranges from 1s to 300s.
Show message
System can pop up a message to alarm you in the local
host screen if you enabled this function.
Buzzer
Check the box here to enable this function. The buzzer
beeps when an alarm occurs.
Alarm upload
System can upload the alarm signal to the centre
(Including alarm centre).
Send Email
If you enabled this function, System can send out an email
to alert you when an alarm occurs.
Tour
You need to click setup button to select tour channel.
System begins 1-wiindow or multiple-window tour display
among the channel(s) you set to record when an alarm
occurs. See Figure 4-53.
PTZ Activation
Here you can set PTZ movement when an alarm occurs.
Such as go to preset X. See Figure 4-63.
Snapshot
Click setup button to select snapshot channel. See Figure
4-54.
4.8.3.4.2 Net Alarm
From main menu->Setup->Event->Alarm->Net alarm, the network alarm interface is shown as in Figure
Network alarm refers to the alarm signal from the network. System does not anti-dither and sensor type
setup. For setup information, please refer to chapter 4.8.3.4.1.
Содержание 600 Series
Страница 1: ...Network Video Recorder User s Manual V 5 0 0 ...
Страница 86: ...76 Figure 3 73 Figure 3 74 Figure 3 75 ...
Страница 94: ...84 Figure 3 83 Figure 3 84 ...
Страница 95: ...85 Figure 3 85 Figure 3 86 ...
Страница 96: ...86 Figure 3 87 Figure 3 88 ...
Страница 98: ...88 Figure 3 90 Figure 3 91 ...
Страница 171: ...161 Figure 4 49 Figure 4 50 ...
Страница 172: ...162 Figure 4 51 Figure 4 52 ...
Страница 179: ...169 Figure 4 61 Figure 4 62 ...
Страница 186: ...176 Figure 4 71 Figure 4 72 ...