Step 3 Configure audio parameters.
Table 6-10 Description of audio parameters
Parameter
Description
Compression
You can select audio
Encode Mode
from
PCM
,
G.711A
,
G.711Mu
,
G.726
,
AAC
,
G.723
.
The configured audio encode mode applies to both audio and
intercom. The default value is recommended.
Sampling Frequency
Sampling number per second. The higher the sampling frequency
is, the more the sample in a second will be, and the more accuracy
the restored signal will be. You can select audio
Sampling
Frequency
from
8000
,
16000
,
32000
,
48000
,
64000
.
Audio Input Type
You can select audio input type from:
●
LineIn
: Requires external audio device.
●
Mic
: Not require external audio device.
Noise Filter
Enable this function, and the system auto filters ambient noise.
Microphone Volume
Adjusts microphone volume.
Speaker Volume
Adjusts speaker volume.
Step 4 Click
Apply
.
6.3 Network
This section introduces network configuration.
6.3.1 TCP/IP
You can configure IP address and DNS (Domain Name System) server and so on according to
network planning.
Prerequisites
The camera has connected to the network.
Procedure
Step 1 Select
>
Network
>
TCP/IP
.
Содержание WizMind IPC-PDBW82041-B360
Страница 1: ...Network Camera Web 5 0 Operation Manual ZHEJIANG DAHUA VISION TECHNOLOGY CO LTD V1 0 0...
Страница 17: ...Operation Manual 8 Figure 3 5 P2P...
Страница 20: ...Operation Manual 11 that is set during the initialization Figure 4 4 Login...
Страница 77: ...Operation Manual 68 Figure 6 61 User Step 2 Click Add Figure 6 62 Add user system...
Страница 120: ...Operation Manual 111 Figure 8 23 Video metadata report...
Страница 153: ...Operation Manual 144 device...
Страница 154: ...Operation Manual...