This manual offers reference material and general information about the basic operation, 

maintenance, and troubleshooting of a Dahua Network PTZ Camera. Read, follow, and retain the 

following safety instructions. Heed all warning on the unit and in the operating instructions before 

operating the unit. Keep this guide for future reference. 

1.1  Important Safeguards and Warnings  

Electrical safety 

 

Install the unit in accordance with the manufacturer’s instructions and in accordance with 

applicable local codes.  

 

All installation and operation must conform to your local electrical safety codes.  

 

Do not overload outlets and extension cords, which may cause fire or electrical shock. 

 

Do not place the camera near or in a place where the camera may contact overhead power lines, 

power circuits, or electrical lights. 

 

Ensure power conforms to SELV (Safety Extra Low Voltage) and that the limited power source is 

rated AC 24V as specified in IEC60950-1. (Power supply requirement is subject to the device 

label). 

 

All input/output ports are SELV circuits. Ensure that SELV circuits are connected only to other 

SELV circuits.  

 

Ground the unit using the ground connection of the power supply to protect the unit from damage, 

especially in damp environments. 

 

Protect the plug and power cord from foot traffic, being pinched, and its exit from the unit. 

 

Units with or without an ON/OFF switch have power supplied to the unit whenever the power 

cord is inserted into the power source; however, the unit is operational only when the ON/OFF 

switch is in the ON position. The power cord is the main power disconnect device for switching 

off the voltage for all units.  

 

Operate the unit only from the type of power source indicated on the label. Before proceeding, 

disconnect the power from the cable to be installed into the unit.  

  For external power supplied units, use only the recommended or approved power supplies. 

  Limited power sources must comply with EN 60950. Substitutions may damage the unit or 

cause fire or shock. 

  For 24 VAC units, voltage applied to the unit’s input power should not exceed ±25%. User-

supplied wiring must comply with local codes (Class 2 power levels). Do not ground the 

supply at the terminals or at the unit’s power supply terminal.  

  Contact the local dealer or the power company to verify the correct power supply.  

 

Do not supply power via the Ethernet connection (PoE) when power is already supplied via the 

power connector.  

 

Do not attempt to service the unit. Opening or removing covers may expose you to dangerous 

voltage or other hazards. Refer all servicing to qualified personnel. 

Содержание /images/6/64

Страница 1: ...2 MP Network PTZ Camera 49925TNI Quick Start Guide Version 001 002 Dahua Technology USA Inc...

Страница 2: ...nd Hardware 6 3 Installation and Configuration 7 3 1 Framework and Dimensions 7 3 2 Wiring 7 3 3 Alarm Setup 8 Alarm Input 8 Alarm Output Level Application 8 Alarm Output Switch Application 9 4 Device...

Страница 3: ...ct the unit from damage especially in damp environments Protect the plug and power cord from foot traffic being pinched and its exit from the unit Units with or without an ON OFF switch have power sup...

Страница 4: ...ng or installation Environmental Precautions Do not aim the unit at a strong light source or into direct sunlight to focus A strong light source may cause overexposure and may affect the longevity of...

Страница 5: ...wipe a dome cover during installation this cover is an optical device Refer to the following methods clean the dome cover Stained with dirt Use an oil free soft brush or blower to gently remove the d...

Страница 6: ...ee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off...

Страница 7: ...y information Dahua accepts no liability for damage resulting directly or indirectly from faults incompleteness or discrepancies between this guide and the product described Dahua is not liable for an...

Страница 8: ...container to transport the unit in the event the unit must be returned for service Retain the carton and all shipping material for future use Please refer to the enclosed CD for more details to view...

Страница 9: ...intended as a reference only Figure 3 1 Dimensions for 49925TNI 3 2 Wiring The dome camera includes the following wiring bundles Wire Color Connection Power 12 VDC Video Control Black RJ 45 Ethernet A...

Страница 10: ...ves the alarm input signal If input signal is grounded then no alarm input signal is detected Figure 3 2 Alarm Output Level Application Use this alarm output configuration if the output triggers an ex...

Страница 11: ...nt substitute as these cards have been fully tested without issue and the SanDisk Extreme line is better suited for constant recording Lower grade SD cards meant for multimedia applications will at ti...

Страница 12: ...de a different permanently earthed metal conduits not supplied Warning Install external interconnecting cables in accordance to NEC ANSI NFPA70 for US application and Canadian Electrical Code Part I C...

Страница 13: ...times the weight of the camera and mount Appropriate tools to mount the camera to the wall Unpacking the Camera 1 Remove the camera the mount accessories and any hardware packages from the boxes 2 Re...

Страница 14: ...rom the dome through the wall mount and pull it out of the other end of the wall mount bracket 6 Align the flange at the top of the dome with the wall mount then push the dome into the bracket Then ti...

Страница 15: ...and automate the assignment of IP addresses DHCP should only be enabled if using dynamic IP address notification or if the DHCP can update a DNS server TFTP The Trivial File Transfer Protocol is a sim...

Страница 16: ...figTool to access and to modify the network settings of a device Refer to the Operation Manual available on the CD included with the camera or on Dahuasecurity com for complete information Notes Ensur...

Страница 17: ...have different Web interfaces the figures below are for reference only and may not represent the Web Interface for your camera Refer to the Web Operation Manual included on the CD shipped with the ca...

Страница 18: ...or Normally Closed NC 3 Check the Relay Out box to enable the alarm activation function 4 Select an alarm output port to activate a corresponding alarm device when an alarm occurs Check Send Email to...

Страница 19: ...following Micro SD card alarm options No SD Card Device triggers an alarm if the device does not contain a Micro SD card Capacity Warning Device triggers an alarm when the data on the Micro SD card pa...

Страница 20: ...to a specified user after the device triggers an alarm 9 Set the capacity limit for the Micro SD Card available with the Capacity Warning event type The device triggers an alarm once the amount of da...

Страница 21: ...logy USA Inc 23 Hubble Irvine CA 92618 Tel 949 679 7777 Fax 949 679 5760 Email sales usa global dahuatech com Rev 001 002 2017 Dahua All rights reserved Design and specifications are subject to change...

Отзывы: