4 Quick Operation
It is to introduce VLAN config briefly in this chapter, please refer to corresponding command line manual
for other detailed config.
4.1 First Login via Console Port
It is the most basic way to log in the local interface via Console port; it is also the method to configure
other ways to log in the device.
Operation Steps
Step 1
Power off the PC.
Step 2
Use default console port cable to connect PC and device. First insert the DB-(hole) plug of console port
cable into the 9-pin serial port of PC, and then insert the RJ-45 plug into the console port of the device.
Note
Please confirm the sign on the port during connection, in case it may plug into the wrong port.
Please plug out RJ-45 and then DB-9 when dismantling console port cable.
Figure 4-1
Step 3
Power on the PC.
Step 4
Run terminal simulation program on the PC; select the serial port which is to connect the device, set the
terminal communication parameters. The parameter value has to be in accordance with the value on the
device, the default is shown as follows.
Baud rate: 115200
Data bit: 8
Stop bit: 1
Parity: none
Flow control: none
Note
If the PC uses Windows Server 2003 operating system, please add super terminal program in the
Windows component and then log in the manage the device according to the way introduced in this
manual; If PC uses Windows Server 2008, Windows Vista, Windows 7 or other operating systems,
please prepare third-party terminal control software, refer to the software operation guide or online help
for operation method.