<operating pressure>
CAUTION : Do not hold your hands under the fuel jet, as there is a rise of injury.
Do not inhale the atomized oil fuel. If possible, work under an extraction system.
5.3.2. Installation
•
Clean seat in cylinder head.
•
Insert nozzle holder with new gasket.
Tighten union nut with 120 N
.
m.
•
Install injection lines free of constraint.
Install leak fuel lines.
CAUTION : The injection lines are designed for high operating pressures and should thus be
handled with particular core.
•
When mounting the pipes to the engine take care of good fitness.
•
Do not bend pipes to permanent deformation. (not for replacing the nozzles either)
•
Do not mount any heavily bent pipes.
•
Avoid bending the pipes at the ends by more than 2 to 3 degrees.
•
In case of faults in the injection system which might have resulted in excessive operating
pressures, not only the failed part but also the injection line has to be replaced.
- 32 -
New nozzle holder
300 + 8 kg/cm
2
Used nozzle holder
285 + 8 kg/cm
2
EA6O5008
EA6O5009
Torque
12 kg.m