10.5. Installation
10.5.1. Inspection Prior to Installation
Measure the correctness of flywheel and flywheel housing. Prior to inspection, clean the
flywheel and flywheel housing.
1) Measuring flywheel housing
Measure the flywheel housing surface
and install the dial gauge (1/1,000) at
the flywheel so as to be vertical to the
flywheel housing, and let the gauge
stem to contact to the flange. Rotate
the flywheel, and measure the
surface error of flywheel housing
flange. The surface error should not
exceed 0.2mm.
2) Measuring bore of flywheel
Housing Attach the gauge as above
so that the gauge stem may contact
the flywheel housing bore as the right
figure. Measure the eccentrics of
flywheel housing bore by rotating the
flywheel. The eccentrics should not
exceed 0.2 mm.
3) Measuring deformation of flywheel
Installing Surface
Fix the dial gauge to the flywheel
housing so as for the gauge stem to
be vertical to the surface to be
installed. The deviation quantity should
not exceed 0.127 mm/inch.
4) Measuring pilot bore of flywheel
Install the gauge as below so as for
the gauge stem to contact to the pilot
bore of the surface to be installed. The
eccentrics of the pilot bore of flywheel
should not exceed 0.127mm at maximum.
- 142 -
Dial gauge
Dial gauge
Flywheel
EFM6017I
Dial gauge
Dial gauge
Flywheel
EFM6018I
Dial gauge
Dial gauge
Flywheel
EFM6019I
Dial gauge
Dial gauge
Flywheel
EFM6020I