42
1) Specifications
4. Specifications, Defect Inspection, and Repairs of Heater
1. Temperature Fuse of Water Heater (184 °C Cutoff
Type)
• If the heater is running without water due to a
malfunction in water level sensor and other
defects, it may cause fire. The inter temperature
fuse is designed to be cut off about a minute after
overheating to prevent such problems. The heater
temperature is set at around 270°C.
• The water heater must be used in water.
Water Heater Water Temperature Sensor
Category
Specifications
Note
Maker
1RCA
Voltage
220V
Power Consumption
1400 W ±5%
Resistance
34.570hm
Current Desnity
11.9
Temperature Fuse
184°C
Thermister
Included in heater
Materials
AISI321
Max. Temperature
WATER
Part Code
3612804000