G420E/G424E
Tier
LP Engine
Advanced Diagnostics
52
Table a. MI-04 Diagnostic Fault Codes (Flash Codes)
DFC
Probable Fault
Action
Corrective Action, First Check
34 MapSensorInputHigh
TMAP sensor failure or shorted circuit
Disable Throttle
Check TMAP connector and MAP
signal wiring for a shorted circuit
TMAP PIN 4 to SECM PIN 5
(SIGNAL)
TMAP PIN 1 to SECM PIN 1 (GND)
TMAP PIN 3 to SECM PIN 18
(XDCR +5VDC)
Check the MAP sensor by
disconnecting the TMAP connector
and measuring at the sensor
TMAP PIN 1(GND) to PIN 4
(PRESSURE SIGNAL KPA) (2.4k
Ω
-
8.2k
Ω
)
TMAP PIN 3(PWR) to PIN 4
(PRESSURE SIGNAL KPA) (3.4k
Ω
-
8.2k
Ω
)
37 IATSensorInputLow
TMAP sensor failure or shorted circuit
Stored Fault Code
(MIL Only)
Check TMAP connector and IAT
signal wiring for a shorted circuit
TMAP PIN 2 to SECM PIN 4
(SIGNAL)
TMAP PIN 1 to SECM PIN 1 (GND)
TMAP PIN 3 to SECM PIN 18 (XDCR
+5VDC)
To check the IAT sensor of the TMAP
disconnect the TMAP connector and
measure the IAT resistance
*See the IAT table in Chapter 6.0
Содержание G15S-2
Страница 3: ......
Страница 5: ......
Страница 61: ...G420E G424E Tier LP Engine Electrical Connections 60 CHAPTER 6 MI 04 ELECTRICAL CONNECTIONS Figure E1...