1. PRECAUTION ...............................................................................................................................................2

2. GENERAL SPECIFICATIONS.....................................................................................................................3

3. NAMES OF MAJOR COMPONENTS ........................................................................................................4

4. FUNCTION OF MAIN COMPONENTS.......................................................................................................5

5. GENERAL INFORMATIONS .......................................................................................................................6

6. CARE AND MAINTENANCE.......................................................................................................................7

7. TROUBLE SHOOTING GUIDE ...................................................................................................................8

8. HOW TO DISASSEMBLE ..........................................................................................................................10

9. WIRING DIAGRAM.....................................................................................................................................11

10. REFRIGERANT CYCLE ..........................................................................................................................12

11. EXPLODED DIAGRAM AND PARTS LIST ...........................................................................................13

Содержание DWB-052C

Страница 1: ...CATIONS 3 3 NAMES OF MAJOR COMPONENTS 4 4 FUNCTION OF MAIN COMPONENTS 5 5 GENERAL INFORMATIONS 6 6 CARE AND MAINTENANCE 7 7 TROUBLE SHOOTING GUIDE 8 8 HOW TO DISASSEMBLE 10 9 WIRING DIAGRAM 11 10 REFRIGERANT CYCLE 12 11 EXPLODED DIAGRAM AND PARTS LIST 13 ...

Страница 2: ...pair the unit and use the measuring appliance adjusted accurately 5 Damage of electric wire and power cord when servicing Check electric wire and a surely replace a damage electric wire and a damage power cord 6 Never use connecting the middle of wire after cutting the middle of wire It may cause a fire and trouble 7 Checking the insulation resistance After you complete the assembly of unit surely...

Страница 3: ...wer Input W 525 W 520 W Running Current A 4 6 A 2 4 A Compressor Type Rotary Model RM5455GQ87 KH 091VFHC Capacitor 40µF 370VAC 13µF 400VAC Model A9520KC030 A9520CC020 Fan Motor Capacitor 4µF 370VAC 2µF 400VAC Indoor Fan Blower Fan Outdoor Fan Propeller Fan Refrigerant R 22 Control Capillary Charge Amount g 13 3oz 380g 14 7oz 420g Dimensions Unit W x H x D PACKING W x H x D Weight Net Weight 45 4 l...

Страница 4: ...AL 3 COOL AIR DISCHARGE 4 GRILLE FRONT 5 KNOB THERMOSTAT 6 KNOB SELECTOR NO PART NAME 7 AIR INTAKE 8 AIR FILTER 9 CONTROL PANEL 10 PLATE WINDOW TOP 11 FRAME WINDOW KIT 12 SHUTTER WINDOW 2 3 8 6 5 1 4 7 0 q w 9 2 3 8 6 5 1 4 7 9 Window kits are optional Item No 10 11 12 ...

Страница 5: ... cooling operation 2 THERMOSTAT TEMPERATURE CONTROL The Thermostat automatically starts and stops operation in order to keep the room temperature at a proper level and this results in efficient use of power and economical cooling Turn clockwise for a cooler room temperature Turn counter clockwise for a warmer room temperature 3 MOTOR The motor is used to rotate the indoor and outdoor fan so that t...

Страница 6: ... accordance with the National Electrical Code 4 USE OF EXTENSION CORDS Because of potential safety hazards under certain conditions we strongly recommend against the use of an extension cord However if you still elect to use an extension cord it is absolutely necessary that it is earthed and the marked rating of the extension cord should be 250V 10A or more for Model DWB 052C Also it is absolutely...

Страница 7: ...zed servicer to ensure unit is functioning properly 2 Wash air conditioner with lukewarm soapy water as needed Rinse and dry thoroughly 3 If using concentrated liquid detergent dilute in warm water first 4 Front grill may be wiped off with a cloth dampened in a mild detergent solution 5 Cabinet may be washed with mild soap or detergent and lukewarm water then polished with liquid wax for appliance...

Страница 8: ... Disconnection 2 Malfunction of contact Disconnection or burned out 1 Failure 2 Malfunction 3 Knob is not set to the proper setting Failure of malfunction of proper setting 1 Disconnection 2 Malfunction of contact Lack of capacity Disconnection 1 The voltage exceeded allowed range 2 Capacity of wire is not sufficient Extremely high Burned out Malfunction Lack of capacity Malfunction Lack of capaci...

Страница 9: ...of refrigerant gas 4 Refrigerant charge is too high Clogged up with dust 1 Fin is cogged up with dust 2 The ventilation is not good 3 The unit is exposed to the sunlight 4 Other heat source is added in the room Installation of the unit is imperfectly done 1 Fan is contacted with obstacles 2 Fixing bolt Have a screw loose Electrical noise The front is lower than rear side 1 Insulation defect of wir...

Страница 10: ...6 Remove wires in the Panel Housing 7 Remove screws 7 point from Ass y Fan Motor s sides Ass y Fan Motor is assembly of Fan Motor Propeller and Blower Fan Orifice and Panel Housing 8 Lift the Ass y Fan Motor from the unit 9 Remove Clip Fan 2 point from the shaft of Fan Motor 10 Remove Propeller Fan from the shaft of Fan Motor 11 Remove Blower Fan from the shaft of Fan Motor 12 Remove Scroll 13 Rem...

Страница 11: ...11 9 WIRING DIAGRAM ...

Страница 12: ...Condenser Propeller fan Capillary tube Compressor Accumulator Blower fan Evaporator M MOTOR 12 10 REFRIGERANT CYCLE ...

Страница 13: ...SCREW TAPTITE 4 TT3 TRS 3X8 MFZN 29 3113800400 LOCK TWIST STANDOFF 1 DASTL 3NA 30 3110700100 BUSHING 1 DACB 012 73MM 31 3111400100 COVER ORIFICE 1 PP M540 32 3111800200 FAN PROPELLER 1 ABS GF 33 3114500300 PLATE SCROLL 1 EPS 34 3113000100 HOLDER EVA 1 SGCC T0 6 35 3110500100 BOX CONTROL 1 SGCC T0 6 36 3111300100 CORD POWER 1 125V 13A SJT3 16AWG DWC 052C 3111300300 CORD POWER 1 250V 16A DWB 052C 37...

Страница 14: ... DWB 052C DWC 052C EXPLODED DIAGRAM ...

Страница 15: ......

Страница 16: ... DAEWOO ELECTRONICS CO LTD 686 AHYEON DONG MAPO GU SEOUL KOREA C P O BOX 8003 SEOUL KOREA TELEX DWELEC K28177 8 CABLE DAEWOOELEC FAX 02 590 6291 TEL 02 360 7114 590 6151 5 http www dwe daewoo co kr PRINTED DATE JAN 2001 ...

Страница 17: ...ELECTRONICS CO LTD S M No DWC052C020 Caution In this Manual some parts can be changed for improving their performance without notice in the parts list So if you need the latest parts information please refer to PPL Parts Price List in Service Information Center http svc dwe co kr ...