Страница 1: ...Manual de Servicio Acondicionador de Aire Tipo Ventana Modelo DWA Y DWC 125CS ...

Страница 2: ...CATIONS 3 3 NAMES OF MAJOR COMPONENTS 4 4 FUNCTION OF MAIN COMPONENTS 5 5 GENERAL INFORMATIONS 6 6 CARE AND MAINTENANCE 7 7 TROUBLE SHOOTING GUIDE 8 8 HOW TO DISASSEMBLE 10 9 WIRING DIAGRAM 12 10 REFRIGERANT CYCLE 13 11 EXPLODED DIAGRAM AND PARTS LIST 14 ...

Страница 3: ...pair the unit and use the measuring appliance adjusted accurately 5 Damage of electric wire and power cord when servicing Check electric wire and a surely replace a damage electric wire and a damage power cord 6 Never use connecting the middle of wire after cutting the middle of wire It may cause a fire and trouble 7 Checking the insulation resistance After you complete the assembly of unit surely...

Страница 4: ...B092HX1JF QK164CBH QK164KBB QJ196KBD Capacitor 45µF 370VAC 50µF 370VAC 30µF 370VAC 25µF 370VAC Model AM12DWD10 OBM 2501K1 AM12DWD10 OBM 2501K1 AM12DWD12 OBM 2502U1 AM12DWD11 OBM 2503U1 Motor Capacitor 12µF 370VAC 12µF 370VAC 5µF 370VAC 4µF 370VAC Indoor Fan Blower Fan Outdoor Fan Propeller Fan Refrigerant R 22 Control Capillary Charge Q ty g 19 8 oz 560g 25 7 oz 730g 26 1 oz 740g 23 6 oz 670g Dime...

Страница 5: ...ADE HORIZENTAL NO PART NAME 8 AIR VENT 9 FRAME GRILLE 10 FRAME GUIDE TOP 11 FRAME WINDOW KIT 12 SHUTTER WINDOW 13 AUTOLOUVERS W DWC 104CS DWC 125CS DWA 125CS DWA 145CS DWC 104CS DWC 125CS DWA 125CS DWA 145CS 4 0 q 7 w 8 3 2 5 6 1 9 9 3 4 8 2 7 1 5 6 9 9 4 0 q 7 w 8 3 2 5 6 1 e 3 4 8 2 7 1 5 6 e DWC 104C DWC 125C DWA 125C DWA 145C ...

Страница 6: ...W FAN This position provides the minimum air flow air flow alone fan operation without cooling operation 2 THERMOSTAT TEMPERATURE CONTROL The Thermostat automatically starts and stops operation in order to keep the room temperature at a proper level and this results in efficient use of power and economical cooling Turn clockwise for a cooler room temperature Turn counter clockwise for a warmer roo...

Страница 7: ...d electrician and have the two prong wall receptacle replaced with a properly grounded three prong wall receptacle in accordance with the National Electrical Code 4 USE OF EXTENSION CORDS Because of potential safety hazards under certain conditions we strongly recommend against the use of an extension cord However if you still elect to use an extension cord it is absolutely necessary that it be a ...

Страница 8: ...r conditioner Have the unit inspected by an authorized servicer to ensure unit is functioning properly 2 Wash air conditioner with lukewarm soapy water as needed Rinse and dry thoroughly 3 If using concentrated liquid detergent dilute in warm water first 4 Front grill may be wiped off with a cloth dampened in a mild detergent solution 5 Cabinet may be washed with mild soap or detergent and lukewar...

Страница 9: ... Disconnection 2 Malfunction of contact Disconnection or burned out 1 Failure 2 Malfunction 3 Knob is not set to the proper setting Failure of malfunction of proper setting 1 Disconnection 2 Malfunction of contact Lack of capacity Disconnection 1 The voltage exceeded allowed range 2 Capacity of wire is not sufficient Extremely high Burned out Malfunction Lack of capacity Malfunction Lack of capaci...

Страница 10: ...of refrigerant gas 4 Refrigerant charge is too high Clogged up with dust 1 Fin is cogged up with dust 2 The ventilation is not good 3 The unit is exposed to the sunlight 4 Other heat source is added in the room Installation of the unit is imperfectly done 1 Fan is contacted with obstacles 2 Fixing bolt Have a screw loose Electrical noise The front is lower than rear side 1 Insulation defect of wir...

Страница 11: ...h fasten Frame Grille with driver Pull knobs out of the control when the knobs are too tight to release leave them Disassemble Frame Grille from chassis 2 Remove the unit from Cabinet Remove screws 2 point from the unit s sides Pull the unit from cabinet 3 Remove Holder Scroll 4 Remove Scroll upper 5 Remove Ass y Control Box Remove screws 4 point Remove wires in the each components 6 Remove wires ...

Страница 12: ...il the snap fit is released 2 Release left lower snap fit Push the left lower side of chassis to the right with pushing right side of Frame Grille to the right until the snap fit is released 3 Pull lower side of the Frame Grille until it is separated from the chassis when knobe remain pull Frame Grille until knobs are released from control 4 Push base side of the Frame Grille to upper side until i...

Страница 13: ...YEL R S C ORG BLK BRN C F DWC 104C DWC 125C DWA 125C DWA 145C WIRING DIAGRAM OFF YEL RED GRY BLU BLU WHT WHT YEL L C 1 6 7 2 4 8 HIGH COOL MED COOL LOW COOL LOW FAN MED FAN FAN MOTOR COMP SWING MOTOR AUTO LOUVER SWITCH SELECTOR SWITCH THERMOSTAT SWITCH O L P CAPACITOR H GRN GRN YEL RED BLK BLK BRN WHT BLU BLK BRN GRN GRN YEL R S C ORG BLK BRN C F DWC 104CS DWC 125CS DWA 125CS DWA 145CS WIRING DIAG...

Страница 14: ...13 Condenser Propeller fan Capillary tube Compressor Accumulator Blower fan Evaporator M MOTOR 10 REFRIGERANT CYCLE ...

Страница 15: ... 94 T0 6 DWC 104C CS 13 3104423140 PIPE SUCTION 1 C1220T 0L DWC 125C CS 3104423170 PIPE SUCTION 1 C1220T 0L DWC 104C CS 14 3100061602 PIPE CAPILLARY AS 1 C1220T 0L DWC 125C CS 3100061670 PIPE CAPILLARY AS 1 C1220T 0L DWC 104C CS 15 3117142600 COMP AS 1 LG QK164CBJ 115V 60HZ DWC 125C CS 3117144300 COMP AS 1 SS 44B092HX1JF 115V 60HZ DWC 104C CS 16 3104425870 PIPE DISCHARGE 1 C1220T 0L DWC 125C CS 31...

Страница 16: ...NG VENT 1 P6 38 3106700400 CAM 1 PCM 39 3118501300 ROCKER SWITCH 1 SSM 1110 DWC 104CS 125CS 40 3107000100 CLIP THERMO 1 ABS HF 380 41 3118500600 THERMOSTAT 1 WK14S 408 120 42 3118501100 SWITCH ROTARY 1 HZ20 6 43 3111372B20 POWER CORD 1 SJT 3 16 AWG 125V 13A 44 3109507400 CAPACITOR 1 370VAC 12 50 ÏF DWC 125C CS 3116907100 CAPACITOR 1 370VAC 12 45 ÏF DWC 104C CS 45 3101201600 CLAMP CAPACITOR 1 SGCC ...

Страница 17: ...ARY AS 1 C1220T 0L DWA 145C CS 15 3117142400 COMP AS 1 LG QK164KBB 208 230V 60HZ DWA 125C CS 3117142300 COMP AS 1 LG QK196KBD 208 230V 60HZ DWA 145C CS 16 3104425870 PIPE DISCHARGE 1 C1220T 0L DWA 125C CS 3104425880 PIPE DISCHARGE 1 C1220T 0L DWA 145C CS 17 3100063500 PIPE COND OUT AS 1 DWC 121C DWA 125C CS 3100063510 PIPE COND OUT AS 1 DWA 145C DWA 145C CS 18 3100063400 PIPE COND IN AS 1 C1220T 0...

Страница 18: ...ITCH 1 SSM 1110 DWA 125CS 145CS 40 3107000100 CLIP THERMO 1 ABS HF 380 41 3118500600 THERMOSTAT 1 WK14S 408 120 42 3118501100 SWITCH ROTARY 1 HZ20 6 43 3111362B30 POWER CORD 1 SJT 3 18 AWG 250V 44 3109507000 CAPACITOR 1 370VAC 5 30µF DWA 125C CS 3109505300 CAPACITOR 1 370VAC 4 25µF DWA 145C CS 45 3101201600 CLAMP CAPACITOR 1 SGCC T0 8 46 3108009700 MOTOR SWING 1 ST 16E 220V 3 15A DWA 125CS 145CS 4...

Страница 19: ...1 DWC 104C CS DWC 125C CS DWA 125C CS DWA 145C CS EXPLODED DIAGRAM ...

Страница 20: ...8 ...

Страница 21: ...C020 DAEWOO ELECTRONICS CORP 686 AHYEON DONG MAPO GU SEOUL KOREA C P O BOX 8003 SEOUL KOREA TELEX DWELEC K28177 8 CABLE DAEWOOELEC FAX 02 590 6291 TEL 02 360 7114 590 6151 5 http www dwe co kr PRINTED DATE JAN 2004 ...