background image

Fabricado bajo licencia de 

Daewoo International Corporation

, Corea

www.daewooherramientas.com.ar

MANUAL DE USO

 DAEQDP SERIES

ELECTROBOMBA

1. INSTALLATION AND OPERATING INSTRUCTIONS

Read these instructions before starting the pump and keep them in a safe place.

Warning!
The pump must not be installed in swimming pools. Ask your specialist electrician for advice.
The pump must not be in operation when people are present at the water outlets where it is used.
Pollution of the liquid could occur due to leakage of lubricants
The pump must not be used when people are in the water when it is used for cleaning and other 
maintenance of swimming pools.

2. PRECAUTION

Do not expose the power outlet to damp.
Do not discharge corrosive liquids (chemicals, cleaning fluids etc…) or abrasives.
Do not expose the pump to frost.
Do not run the pump without water.
Keep children well away from the working area.
Never carry the pump by its cable and do not pull the cable to disconnect it.
Do not modify the inside of the pump or the float, because the device may no longer be sealed. 
Call in a specialist if necessary.
The fingers mustn't insert into the water  inlet and water outlet when the pump is operating.
This appliance is not intended for use by persons (including children) with reduced physical, sen-
sory or mental capabilities, or lack of experience and knowledge, unless they have been given 
supervision or instruction concerning use of the appliance by a person responsible for their safety.
Children should be supervised to ensure that they do not play with the appliance.
When the pump intended to be connected to the water mains, additional backflow prevention device 
shall be set to prevent backsiphonage of non-potable water into the water mains.

Installation
This pump is designed for exclusively domestic installation:
In places where there is a risk of flooding.
In sumps or wells.

Keep an empty space around the pump so that the float switch can work without being blocked 
(e.g. use a sump at least 40x40x50 cm).
The pump is designed to run in liquid not exceeding 350C.
It can be installed:
With either a fixed conduit.
Or a flexible conduit.
It must be fixed by the handle provided for the purpose or set at the bottom of the sump
 (it must be clean with no impurities or sludge)
If water level is low (long period of drought), be careful to ensure that any impurities or sludge, after 
drying, do not prevent the pump from starting up. Consequently, you must make sure that the site 
where the pump is installed is clean and run the pump from time to time.
The appliance can only be used at the upward  position.

11. EXPLODED VIEW AND PART LIST DAEQDP70-P

3. MAINS SUPPLY

Before starting up the pump make sure that:
- The pump is to be powered by a residual differential current device, with a rated operating diffe-
rential current not exceeding 30 mA.
- The mains supply voltage matches the voltage indicated on the pump identification plate (230-
v~/50Hz).
Ask your specialist electrician for advice.
Make sure that the fuse protecting the power outlet is at least 6 amps.

Warning!
If the power cable is damaged, it must be replaced by a professional to avoid the risk of danger.

Commissioning
After installing the pump as indicated in these instructions, it is ready to work.

4. SERVICING

Disconnect the power outlet before making any adjustments or performing servicing operations.
The pump does not require any specific maintenance but for longer life we recommend that you 
check and clean the area in which the pump is installed (every three months, for example).
For temporary use, clean the pump with clean water after using it.

5. CLEANING THE TURBINE

(Remove the plug from the power outlet before cleaning operations start)
If there are heavy deposits in the pump body, the lower part must be dismantled as follows:
1. Remove the 4screws from the lower side of the suction basket.
2. Detach the suction basket from the body of the pump.
3. Clean the pump with clean water.
Warning! Do not put down the pump on the turbine nor hold it by this point either!
4. For reassembly, repeat the above operations in reverse order.

6. SETTING THE SWITCH POINT

(The float switch point can be set by adjusting the notches.
Check the following points before switching on:
·The float switch must be installed so that the switch point level can be reached easily with very little 
effort. Make sure of this as follows: immerse the pump in a container full of water and lift the float 
switch carefully by hand, then lower it. You can thereby check that the pump starts and stops.
·Make sure that the gap between the head of the float switch and the float switch anchorage device 
is not too small. If the gap is not wide enough, perfect operation is not guaranteed.
·Concerning adjustment, make sure that the float switch does not touch the floor before the pump 
has stopped. Warning! Risk of running dry.
·To modify the starting level, slide the float cable into the notch provided for the purpose on the 
handle.

7. ANOMALIES – SOURCES – REMEDIES

8. DISPOSAL

              “Electrical products must not be thrown out with domestic waste. Recycle them at the        
F             special disposal centres provided for the purpose. Contact your local authorities or stocJ   
L             kist for advice on recycling”.

9. TECHNICAL DATA

DAEQDP35-P

Power: 400 W
Max flow rate: 7000 L/min
Max delivery head: 7 m 
Max pressure: 0,7 bar 
Power cable length: 10 m
Max delivery temperature: 35 C°
Max immersion depth: 5 m
Max grain size: 5 mm

10. EXPLODED VIEW AND PART LIST DAEQDP35-P

Содержание DAEQDP Series

Страница 1: ...Fabricado bajo licencia de Daewoo International Corporation Corea www daewooherramientas com ar MANUAL DE USO DAEQDP SERIES ELECTROBOMBA...

Страница 2: ...CAUTION 2 3 MAINS SUPPLY 3 4 SERVICING 3 5 CLEANING THE TURBINE 3 6 SETTING THE SWITCH POINT 3 7 ANOMALIES SOURCES REMEDIES 4 8 DISPOSAL 4 9 TECHNICAL DATA 4 10 EXPLODED VIEW AND PART LIST DAEQDP35 P...

Страница 3: ...h reduced physical sen sory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible fo...

Страница 4: ...start If there are heavy deposits in the pump body the lower part must be dismantled as follows 1 Remove the 4screws from the lower side of the suction basket 2 Detach the suction basket from the bod...

Страница 5: ...is clogged The discharge pipe is stuck Clean the intake filter with a water jet Release the pipe The pump won t stop The float switch is blocked in the upper part Release the float and r eposition th...

Страница 6: ...5 10 EXPLODED VIEW AND PART LIST DAEQDP35 P...

Страница 7: ...12 Gasket 13 Earth wire 14 Gasket 15 Stator 16 Elbow 17 O ring 18 Output connector 19 NO Description 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 Washer Skeleton seal ring Front motor cov...

Страница 8: ...7 11 EXPLODED VIEW AND PART LIST DAEQDP70 P...

Страница 9: ...Gasket 15 Stator 16 Elbow 17 O ring 18 Output connector 19 NO Description 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 Washer Front motor cover Skeleton seal ring Mechanical seal Jump ring...

Страница 10: ...ario sobre la superficie del cilindro y el pist n y la destrucci n de los anillos de pist n Adem s la garant a no cubre fallas de reguladores de energ a de tensi n autom ticos debido a la operaci n in...

Страница 11: ...www daewooherramientas com ar Fabricado bajo licencia de Daewoo International Corporation Corea...

Отзывы: