- 4 -
Adjustments
1. TAPE SECTION
Test Tape be used
HEAD ADJUSTMENT (AZIMUTH)
1. 10KHz test tape(example: MTT-114N) must be used for this adjustment.
2. Connect to VTVM or oscilloscope to the headphone jack or speaker terminal.
3. Press the play button.
4. Adjust the azimuth by using a screw driver to maintain the max. L&R output voltage.
5. Adjust tape A(1), tape B(2) respectively, Please secure the azimuth position by using locking paint.
RECORDING BIAS OSCILLATOR FREQUENCY ADJUSTMENT
1. Connect the frequency counter to TP603, GND.
2. Press the REC button.
3. Adjust L603 to obtain 80 KHz
±
100Hz
Tape
Contents
Use
MTT-111N
3 KHz
Tape Speed Adjustment
MTT-114N
10 KHz
Head Azimuth Adjustment
MTT-5511
Blank
Record Frequency Property
VTVM
Scope
R-CH
L-CH
47 kohm
47 kohm
Input Level
Measurement
Point
Input Point
Output Level
Measurement
Point
TAPE ALIGNMENT CHART
Step
Item
Reference Value Test Tape Adjust Point
Test Point
Note
FIG.
1
Tape Speed
Adjustment
Normal
3,015~3,025Hz
MTT-111N RV601
Line Out L/R
Channel
Confirm Wow & Flut-
ter is within 0.35%
FIG.1
3,000~3,010Hz
MTT-111N RV601
Line Out L/R
Channel
Confirm Tape Speed
of end position after
adjustment at tape
start position
FIG.1
High
5,820~6,180Hz
MTT-111N - - - - - -
Shorted
TP601,
TP602
Confirm High speed
after normal speed
adjustment
FIG.1
2
Azimuth Adjustment
Maximum Level
Phase:Within90°
MTT-114N Head Screw
Line Out L/R
Channel
FIG.2,3,4
3
Recording Bias Oscilla-
tor Frequency Adjust-
ment
80 KHz
±
0.5
MTT-5511
L603
TP603,GND
Adjust with frequency
counter connected.
FIG.1
FIG. 1 : Tape Speed & Record Bias Oscillator
Frequency Adjust Circuit
Test Tape : MTT-111N(3kHz)
MTT-5511(Blank)
Frequency Counter
Output Level
Measurement Point
Set
FIG. 2 : Tape Azimuth Adjust Location
(Record/Playback Head)
FIG. 3 : Tape Azimuth Adjust Head Screw & Waveform
FIG. 4 : Tape Azimuth Adjust Circuit & Waveform
Forward
Side
Reverse
Side
Adjust with Frequency
Counter Connected
L-CH
Peak
R-CH
Peak
Screw
Angle
O
u
tp
u
t
L
e
v
e
l
within
1 dB
within
1 dB
L-CH
Peak
R-CH
Peak
Screw Angle
V
H
Oscilloscope
L-CH
Output Level
Measurement Point
Set
Test Tape
MTT-114N
(10kHz)
Screen Pattern
In Phase 45 90 135 180
Good
Wrong
Содержание AXL-125
Страница 1: ...Service Manual MINI COMPONENT SYSTEM Model DAEWOO ELECTRONICS CO LTD AXL 125 R ...
Страница 6: ...Exploded View and Mechanical Parts List Model No XL 125 R 5 AXL 122L 124L 125R 123DP 125DP 128L ...
Страница 10: ...BLOCK DIAGRAM 9 Model No XL 125 R ...
Страница 12: ...Schemetic Diagram 11 Model No XL 125 R Ass y Name CD ...
Страница 13: ...Schemetic Diagram 12 Model No XL 125 R Ass y Name CONTROL ...
Страница 14: ...P C B Pattern Layout Model No XL 125 R Ass y Name Main PCB 13 ...
Страница 15: ...Model No XL 125 R Ass y Name CD P C B P C B Pattern Layout 14 Model No XL 125 R Ass y Name PT ...
Страница 16: ...P C B Pattern Layout 15 Model No XL 125 R Ass y Name CONTROL ...