6
Installation Specifications
Cutout Dimensions
Stiffener
Cabinet face
Countertop
Floor
3/8” min. (1.0 cm) space
behind raised vent
chassis to clear stiffener
3/8” min. (1.0 cm)
flat countertop overhang
required behind cutout
ERV or PRV series raised
vent: Check raised vent
dimensions/specifications
to determine proper fit
SGM series cooktop
Stiffener
Cabinet face
Countertop
Floor
5/8” min. (1.6 cm) space
behind raised vent
chassis to clear stiffener
4 5/8” (11.7 cm)
9 7/8” (25.1 cm) with
CABP3 blower installed
5/8” min. (1.6 cm)
flat countertop overhang
required behind cutout
RV series raised vent:
Check raised vent
dimensions/specifications
to determine proper fit
SGM series cooktop
Side View - SGM Series Cooktop with
ERV or PRV Series Raised Vent
Side View - SGM Series Cooktop with
RV Series Raised Vent
All tole1/16” (+1.6 mm), -0, unless otherwise noted.
IMPORTANT:
Be careful to use the correct cutout diagram (on the facing page) to determine the countertop dimensions
for the installation type. Carefully double check all dimensions against the table below and the correct diagram before cut-
ting the countertop.
Countertop Dimensions
Installation Type
Cutout
Diagram
C Min.
D
E
F
G
H
SGM304 without raised
vent
Figure 1
(Square)
2 7/8”
(7.3 cm)
19 3/4”
(50.2 cm)
27 3/4”
(68.6 cm)
NA
NA
NA
SGM304 with ERV30,
ERV3015 and PRV30
Figure 1
(Square)
3/8”
(1.0 cm)
22 1/2”
(57.2 cm)*
27 3/4”
(68.6 cm)
NA
NA
NA
SGM304 with RV30
Figure 1
(Square)
5/8”
(1.6 cm)
22 1/4”
56.5 cm)*
27 3/4”
(68.6 cm)
NA
NA
NA
SGM365 without raised
vent
Figure 1
(Square)
2 3/8”
(6.0 cm)
19 3/4”
(50.2 cm)
33 5/8”
(85.4 cm)
NA
NA
NA
SGM365 with ERV36,
ERV3615 and PRV36
Figure 1
(Square)
3/8”
(1.0 cm)
22 1/2”
(57.2 cm)*
33 5/8”
(85.4 cm)
NA
NA
NA
SGM365 with RV36
Figure 1
(Square)
5/8”
(1.6 cm)
22 1/4”
(56.5 cm)*
33 5/8”
(85.4 cm)
NA
NA
NA
SGM466 without raised
vent
Figure 1
(Square)
2 7/8”
(7.3 cm)
19 3/4”
(50.2 cm)
44 3/4”
(113.7 cm)
NA
NA
NA
SGM466 with PRV46
Figure 2
(Notched)
3/8”
(1.0 cm)
22 1/2”
(57.2 cm)*
44 3/4”
(113.7 cm)
43 1/2”
(110.5 cm)
5/8”
(1.6 cm)
2 5/8” **
(6.7 cm)
SGM466 with RV46
Figure 2
(Notched)
5/8”
(1.6 cm)
22 1/4”
(56.5 cm)*
44 3/4”
(113.7 cm)
43 1/2”
(110.5 cm)
5/8”
(1.6 cm)
2 3/8” **
(6.0 cm)
* Total cutout depth, accommodates both the cooktop and raised vent
**
IMPORTANT:
Notch depth is included in total cutout depth
(D)
.
DO NOT
add notch depth to total cutout depth
(D)
.
Содержание SGM466BLP
Страница 1: ...Installation Instructions Models SGM304 SGM365 SGM466 Gas Cooktop Part No 65141 Rev M...
Страница 14: ...12 Wiring Diagrams...
Страница 15: ...13 Wiring Diagrams...
Страница 16: ...14 Wiring Diagrams...
Страница 17: ...15 Notes...
Страница 18: ...16 Notes...
Страница 19: ......
Страница 20: ...Dacor 14425 Clark Avenue City of Industry CA 91745 Phone 800 793 0093 Fax 626 403 3130 www dacor com...