background image

6

Cabinet and Countertop Layout

 WARNING

•  To reduce the risk of personal injury caused by 

reaching over a hot appliance, avoid locating cabinet 

storage space directly above the cooktop.

•  Failure to meet or exceed the maximum and mini-

mum dimensions/clearances stated in these instruc-

tions may result in a fire hazard.

•  Follow the countertop manufacturer’s instructions 

regarding the minimum corner radius, use of heat 

reflective tape, reinforcement of corners, etc.

•  Carefully check the location where the cooktop will be 

installed. For best performance, the cooktop should be 

placed away from drafts that may be caused by doors, 

windows, and heating and air conditioning vents. 

•  This appliance is to be used in conjunction with a suit-

able vent hood or approved Dacor downdraft vent.

Refer to the following illustrations, notes, and tables for 

clearance allowances.

Installation Specifications

Minimum Required Clearances

Around the Cooktop

All tolerances: +1/16” -0” unless otherwise noted.

•  Allow a minimum 1/4” (6 mm) clearance between the 

bottom of the cooktop chassis and all combustible sur-

faces, including the upper edge of a drawer installed 

below the cooktop.

Model

(B) Minimum

RNCT305G

29 1/4” (74.3 cm)

RNCT365G

35 1/4” (89.5 cm)

Under Cabinet Clearances

•  The gas supply piping, gas shut-off valve and the elec-

trical outlet must be located so that they do not inter-

fere with the cooktop when it is installed. If installing 

another appliance in the cabinet below, allow for the 

routing of gas and electrical service behind it.

The installation must allow for the following:

•  Access to the gas shut-off valve and regulator when 

the unit is installed. 

•  Access to the electrical outlet when the cooktop is in 

place. The 42” (106.7 cm) power cord must be able to 

reach the electrical outlet.

•  Access to the underside of the cooktop for service and 

inspection purposes.

•  Clearance inside the cabinet to allow for proper hold 

down bracket installation.

To allow access to the utilities and cooktop bottom, a fixed 

shelf should not be installed below the cooktop. See the 

following pages for countertop cutout dimensions.

Downdraft Compatibility

If installing the cooktop with a downdraft, use only the 

approved Dacor downdraft model numbers below.

Cooktop Model

Approved Downdraft 

RNCT305G

ERV3015

RNCT365G

ERV3615

1/4” (6 mm)

mimimum clearance

to combustible

surfaces

 B

 * Allows for clearance between hold down brackets

Model

(A) Minimum

(A) Recommended

RNCT305G

30” (76.2 cm)

36” (91.4 cm)

RNCT365G

36” (91.4 cm)

42” (106.7 cm)

13” max.

3

(33.0 cm)

3

 This specification does not apply for cabinets located 

   greater than a horizontal distance of 

 

5 1/2” (14.0 cm) from

   edge of cooktop. Allow 6 7/8” (17.5 cm) 

 

from cutout edge.

A

 1 5/8” min. 

(4.1 cm)

Combustible 

surface to rear

30” min.

1, 2

(76.2 cm)

See cutout

dimensions

See cutout

dimensions

2

 If installing with an overhead range hood, check the hood 

  

 

specifications for minimum required clearances.

1

 Distance to combustible surfaces measured from cooking 

   surface (top of cooktop grate).

  18” min.

1, 3

(45.7 cm)

Содержание RNCT305G

Страница 1: ...Installation Instructions Renaissance Series Gas Cooktop Models RNCT305G RNCT365G Part No 109327 Rev A...

Страница 2: ...umer Keep these Installation Instructions for future reference and for the local electrical inspector s use Note Dacor is not responsible for service required to correct a faulty installation 2015 Dac...

Страница 3: ...ppliance Do not touch any electrical switch or use any electri cal devices including the telephone in your building From a neighbor s phone immediately call the gas supplier Follow the gas supplier s...

Страница 4: ...of the appliance WARNING General Safety Precautions To reduce the risk of fire electric shock or serious injury or death when using your appliance follow basic safety precautions including the followi...

Страница 5: ...its equipped for high altitude operation have an H at the end of the model number listed on the product data label Units equipped for LP operation have LP in the model number listed on the product dat...

Страница 6: ...tion Product Dimensions Front of unit Power cord 42 106 7 cm long 1 2 male NPT gas inlet 2 5 1 cm 1 3 4 4 4 cm 1 2 male NPT gas inlet Power cord Chassis Front of cooktop Top panel overhang Gas inlet e...

Страница 7: ...2 cm chassis height Model A width B width RNCT305G 30 76 2 cm 27 5 16 69 4 cm RNCT365G 36 91 4 cm 33 5 16 84 6 cm Side View Rear overhang Front overhang 19 9 32 49 0 cm 17 32 1 3 cm 1 3 16 3 0 cm Fron...

Страница 8: ...If installing another appliance in the cabinet below allow for the routing of gas and electrical service behind it The installation must allow for the following Access to the gas shut off valve and r...

Страница 9: ...in 4 1 cm Configuration C Minimum D E F Minimum RNCT305G with no downdraft 3 1 4 8 3 cm 19 5 8 49 9 cm 27 5 8 70 2 cm 6 7 8 17 5 cm RNCT305G with ERV3015 downdraft 3 8 1 0 cm 22 3 4 57 8 cm 27 5 8 70...

Страница 10: ...when tightening gas connections and fittings Do not use Teflon tape or plumber s putty on flexible gas line connections Before use test the gas lines for leaks as instructed Do not use a flame to che...

Страница 11: ...operly function unless all of the burner pieces are correctly seated 3 Gently set the grates on top of the spill tray Make sure that the feet are placed in the indentations located in the spill tray M...

Страница 12: ...back of the cooktop The notches on the left and right grates fit in the sides of the cooktop 3 Gently lower the legs of the grates into their corresponding indentations on the cooktop NOTE The burner...

Страница 13: ...the control knob from HIGH toward LOW to adjust the flame height SimmerSear burners turn the control knob to the simmer setting and make sure the low level flame can be adjusted Make sure the burner i...

Страница 14: ...e for the cooktop located and installed according to these instructions and in accordance with all applicable codes See page 3 Has the gas supply inlet pressure been measured to ensure that it does no...

Страница 15: ...all wires prior to disconnection when servicing controls Miswiring can cause malfunction and dangerous operation Verify that the unit is working correctly after servicing 120 Vac 60 Hz Power Pupply W...

Страница 16: ...Dacor 14425 Clark Avenue City of Industry CA 91745 Phone 800 793 0093 Fax 626 403 3130 www dacor com...

Отзывы: