![Dacor DTG36M955F Скачать руководство пользователя страница 32](http://html1.mh-extra.com/html/dacor/dtg36m955f/dtg36m955f_installation-instructions-manual_3270483032.webp)
Converting the pressure regulator
NOTE
If you use LP gas, these steps and conversions must be made
before
adjusting the flames.
1.
Using your fingers, turn the cap. And carefully look at the spring retainer to locate the
NAT or LP position.
LP
LP
LP
LP
NAT
NAT
NAT
NAT. Position
L.P./Propane
Position
Pressure Regulator
Spring
Retainer
NAT
Cap
Gasket
LP
2. Rotate the spring retainer 90°, and pull it from the cap. Turn the spring retainer over
so LP shows, re-insert it in the cap, then rotate it 90° into position.
3. Screw the cap back onto the regulator, and tighten the cap.
3
2
English