WARNING:
Part No. 100807 Rev. D
If the cooktop enclosure has a floor directly
below the chassis, it
must
be ventilated.
IMPORTANT:
These instructions apply only to installations with an enclosed floor directly below the chassis.
STEP 1:
Construct or modify the cabinet floor to proper dimensions.
See the cooktop installation instructions for additional dimensions and information.
STEP 2:
Install ventilation holes in the cabinet floor.
4” (chassis height)
2” minimum to
combustible
enclosure floor.
Floor may be mounted so that it is flush to
chassis bottom if it is
not
combustible.
FRONT VIEW
3/4
”
7
3/4
” X 4
3/8
” ventilation cutouts in enclosure floor
1
1/2
”
1
1/2
”
Cooktop cutout
in top of cabinet
3/4
”
TOP VIEW
Ventilation Duct Kit PN: ATD323
INSTALLATION
INSTRUCTIONS
Cooktop Models ETT365-2 and METB365-1