dacell AM-1000 Скачать руководство пользователя страница 1

 

 

 

 

 

 

MODEL : AM-1000             

DYNAMIC STRAIN AMPLIFIER 

 

  USER’S MANUAL 

 
 
 
 
 

 

 

 

DACELL CO.,LTD. 

 

Address: 681-1, Cheoksan-Ri, Nami-Myeon, Cheongweon-Gun, 

Chung-Buk, 363-810 Korea 

TEL: 82-43-260-2242 

FAX: 82-43-260-2245 

http://www.dacell.com 

E-Mail: [email protected] 

 

Содержание AM-1000

Страница 1: ...YNAMIC STRAIN AMPLIFIER USER S MANUAL DACELL CO LTD Address 681 1 Cheoksan Ri Nami Myeon Cheongweon Gun Chung Buk 363 810 Korea TEL 82 43 260 2242 FAX 82 43 260 2245 http www dacell com E Mail dana da...

Страница 2: ...11 4 1 POWER CONNECTION 11 4 2 SENSOR CONNECTION 11 4 3 INPUT HIGH LEVEL VOLTAGE 14 4 4 NOTES FOR SELECTING SENSOR CABLE 14 4 5 NOTES FOR DYNAMIC MEASUREMENT 14 4 6 NOTES FOR STATIC MEASUREMENT 15 4 7...

Страница 3: ...to Zero Balance method is used for Zero Span This device can use connection for Quarter Half Full bridge type of strain gauge It is designed to install on standard 19 Sub rack 2 SPECIFICATION 1 Measur...

Страница 4: ...alibration CAL Extent 1 F S 1 0mV V 2000 strain 0 1mV V 200 strain 13 Sensitivity adjustment GAIN X1 X10 X100 X400 X1000 within 1 at error each point SPAN X1 X11 continuous variableness FINE X1 X2 con...

Страница 5: ...t within 0 05 F S Sensitivity change within 0 05 F S 20 MONITOR Digital Voltage Display Over 10V will be displayed in 10 00 increased or decreased in each 0 01 Less 10V will be displayed in 0 000 incr...

Страница 6: ...7 Bridge voltage fine control volume 8 Bridge voltage senscing selecting switch 9 Internal CAL Bridge resistance selecting switch 10 CAL Strain value switch 11 GAIN selecting switch 12 GAIN control vo...

Страница 7: ...2 Back Panel 19 Low current output load more than 2k 20 High current output load more than 200 21 Sensor input connector 22 Case earth terminal 23 Fuse 24 Power selecting switch 25 Power input connec...

Страница 8: ...will appear on the LED and then zero will be set 6 Bridge voltage selecting switch This switch is to select the bridge supply voltage You can make your selection for the supply voltage among DC 1V 2V...

Страница 9: ...ltage monitor terminal This can monitor Sensor output voltage 18 Signal output monitor terminal This can monitor output voltage of Amplifier 19 Low current output more than 2k load connector It is the...

Страница 10: ...9 24 Power selecting switch It is a selection AC 110V 220V switch AC 220V when deliver from a warehouse 25 Power input connector This connector is to supply external AC power...

Страница 11: ...ch and then supply power to the device If the lamp is not lighted please check the fuse and power selecting switch 4 2 Sensor connection Connector is MIL C MS3112 14 19 connector of MIL C 26482 Series...

Страница 12: ...11 ST AM1000 INTERNAL CIRCUIT Internal Dummy External Dummy Quarter Bridge connection...

Страница 13: ...12 Prefered Alternate Half Bridge connection 4 Gauge Transducer Full Bridge connection...

Страница 14: ...rature change 3 The input stage of amplifier are SIG SIG Since their minimum input current is originated by this input impedance it should be over 50mA to carry out the measurement 4 4 Notes for selec...

Страница 15: ...value can be changed by the surrounding temperature Please pay your special attention for this point Please carry out the following procedures 1 You must us 3 line for Quarter Bridge 2 To minimize the...

Страница 16: ...ve gauge To control the sensor proper voltage of the amplifier please turn the bridge voltage switch 4 9 Bridge balance Generally when the bridge balance is too much out you cannot carry out the measu...

Страница 17: ...ance or proper voltage while stress analysis is being done So shunt compensation is very important when you set the amplifier gain Also when you use the analogue transducer force torque and pressure e...

Страница 18: ...17 L P F Characteristic GAIN Band Width Characteristic...