The Pump and DConnect Box 2
do not connect to each other (PLC
DCONNECT BOX2 led steady
red)
(paragraph 10)
They are galvanically separated.
Check that the two units are on the same power
supply and in the same phase.
They are too far apart.
Connect the two units at a shorter distance.
The two units are not associated (only in case of
replacement of a unit)
Perform the association procedure
The pump does not start and the
status signals error E17
Blocked rotor
•
Update Fw version to the latest available
•
Wait 25 minutes with the machine
powered
for the automatic restoration of the blocked
status
•
Check that the shaft turns freely
The pump does not start, the
status indicates one of the
following errors: E19, E20, E21,
E22, E23, E24
SW safety error
It is necessary to wait 25 minutes with the machine
powered for the automatic restoration of the locked
status.
Table 7 Troubleshooting
11
FIRMWARE UPDATE
The ESYBOX DIVER firmware can be updated via cloud or app using DConnect Box 2.
When a new firmware is available, the interface sends a notification and gives the user the opportunity to start the update..
12
CLEANING STORAGE MAINTENANCE
The pump does not require any maintenance. Frost can damage the pump. In very cold temperatures, remove the pump from the
liquid, empty it and store it away from frost. Before any cleaning work is carried out, the pump must be disconnected from the power
mains.
Once the pump has been removed from the liquid, it is advisable to clean the following parts with a simple jet of water:
- Filter (open, see figure 1A)
- Suction filter with float, in case of version X (see figure 3)
- Non-return valve. In this case, remove the part concerned as shown in figure 11.
Be sure to reassemble all parts correctly.